Instruction Manual
  15
 Initialization 
DF3033ST and DFG3033 Models
1.  Ensure that power is supplied 
through main service panel.
2.  Ensure the Main On/Off Switch 
located in the switch box on 
the replace in the upper right 
hand corner is in the 
 On 
position (Figure 19A).
ABC
Figure 19
DF3033ST / DFG3033 
Manual controls
3.  Set the 3 Position Manual 
Control (Figure 19B) to the 
Remote position (left position).
4.  Press and hold the 
Initialization Button on the unit 
(Figure 19C).
5.  While holding the Initialization 
Button, press any button 
on the Wall Switch Remote 
Control.
6.  Release the Initialization 
Button and button pressed 
on the Control, sender is 
initialized with the replace.
 Operation
Manual Controls
The following instructions will 
cover the operation of the manual 
controls installed with the receiver 
board contained with this kit 
(BF unit installations). For the 
operation of manual controls 
for other installations (BLF50, 
DF3033ST and DFG3033), 
please consult your Owner's 
Manual for those specic models.
The replace can be controlled 
with switches located on the 
receiver as shown in Figure 20.
!
  NOTE: Firebox must have 
the Main On/Off and mode 
selector switch in the full on 
position for all features to work 
properly.