Specifications
7211270100 Rev03 5
Wiring the RTEV99 Internal Thermostat
As per the RTEV99 Instructions, fasten the sensor probe assembly by the supplied screws on
the base next to the fan. There are four wires:
• The white wire marked LE is wired into lower terminal block #7.
• The white wire marked LH is wired into lower terminal block #10.
• The two wires crimped together are wired to the lower terminal block #8 and jumpered to the
upper terminal block #5 / N.
• The brown wire marked L is pre-wired to a 2-pole terminal block at #12. This terminal block
is to be connected to the pre-drilled holes under the main terminal block and then wired to
upper terminal block #2 – L1 to complete the circuit.
Wiring by installer
- - - - Pre Wired