Specifications
DCP2010 Control Settings – Nova Scotia Appendix B
Customer Name: __________________________ Installation Company: _____________________
Address: ________________________________ Installer Phone # ________________________
________________________________ Date: __________________________________
Position
Set switch Description Enter Setting
1
2
3
Off
Off
On
Mid-Peak Off-Set (in hours) 5 hours
(the time from the end of off-peak to the start of mid-peak)
4
5
6
On
On
Off
Mid-Peak Duration (in hours ) 4 hours
7 Off Stepped delay 5 minutes in sequence
8 On Rate Signaling, Open contact for Off-Peak
Operator menu
abbreviation
Operator menu designation
Operator menu
factory default
Enter Setting:
LA Runtime 0 h 0 h
E5 Charge level 0 % 0 %
E2 Charge start 15° C 15° C
E15 Base charge start 15 % 15 %
E10 Additional charging 85 % 85 %
ATW Effective external temperature
External
temperature display
Timer Real-time timer No
TAE Day setting T 1
Operator Menu
ANZ Display
Technician menu
abbreviation
Technician menu designation
Technician menu
factory setting
Enter Setting:
E1 Full charge - 12° C
E3 Main charging duration 7 h 7h
E4 Minimum charging base 25 % 25%
TAS Daytime skip E1 E1
TU Daytime switching 10 h
SEH Lock 6 h
UMD Circulation period 22 h 22h
ATM External temperature averaging Yes Yes
FSU
Release synchronization with
timer
No
LFS
Earliest
start of release
21:00
LFD
Maximum
duration of release
8 h 8 h
LZS
Earliest start
of additional release
14:00
LZD
Maximum additional
release duration
0 h
Technician Menu
SHT
Daytime heating contactor
activation
No No