Technical data

1133..00 CCHHAANNGGIINNGG CCOOMMPPOONNEENNTTSS
1133..66 FFLLUUEE//HHEEAATT TTEEMMPPEERRAATTUURREE TTHHEERRMMOOSSTTAATT
1. Disconnect the electrical plug.
2. Turn the sensor 90° anticlockwise to remove - it is a
bayonet connection (Fig. 60).
3. Reassemble in reverse order.
© Dimple
x Boiler
s 2008
3333
1133..77 TTHHEERRMMAALL FFUUSSEE
1. The thermal fuse is non-changeable. If the fuse fails contact
Dimplex Technical Department.
1133..88 CCEENNTTRRAALL HHEEAATTIINNGG FFLLOOWW TTEEMMPPEERRAATTUURREE TTHHEERRMMIISSTTOORR
1. Di
sconnect the electrical plug.
2. Ease the sensor clip away from the pipe and remove (Fig. 61).
3. Reassemble in reverse order.
1133..99 CCEENNTTRRAALL HHEEAATTIINNGG RREETTUURRNN TTEEMMPPEERRAATTUURREE TTHHEERRMMIISSTTOORR
1. Disconnect the electrical plug.
2. Ease the sensor clip away from the pipe and remove (Fig. 61).
3. Reassemble in reverse order.