Installation manual
4.8 Connection arrangement for SUTP Mid Range Cylinder
Fig 1
1
MAINS COLD WATER SUPPLY (15mm)
2
STOP COCK (NOT SUPPLIED)
3
PRESSURE REDUCING VALVE
4
CHECK VALVE if supplied separately (included in RWC expansion relief valve)
5
EXPANSION RELIEF VALVE - SET 6 BAR
6
DISCHARGE PIPE 22mm DIA (SEE SECTION 7)
7
DRAIN COCK (Not Supplied)
8
TUNDISH
9
EXPANSION VESSEL
4.9. Discharge arrangement.
The Tundish must be installed in a position so that it is clearly visible by the user. In addition, the
discharge pipe from the Tundish should terminate in a safe place where there is no risk to persons in
the vicinity of the discharge, be of metal and:
(a) Be at least one pipe size larger than the normal outlet size of the safety device unless its total
equipment hydraulic resistance exceeds that of a straight pipe 9 m long, i.e. discharge pipes between 9
m and 18 m equivalent resistance length should be at least two sizes larger then the normal outlet size
of the safety device, between 18 m and 27 m at least three sizes larger and so on. Bends must be taken
into account in calculating the flow resistance. Refer to the diagram, tables and worked example
detailed in Fig 2.
6