Technical data
- 1 - 
Dimplex SmartRad fan convector 
Models: SRX 80, SRX 120, SRX 140 & SRX 180 
PLEASE STORE THESE INSTRUCTIONS IN A SAFE PLACE. 
Important safety information 
The  air  inlet  and  outlet  guards  must  not  be  covered  or 
blocked. 
Before performing  maintenance work on the device, discon-
nect it from the power supply. 
THE DEVICE MUST BE GROUNDED. 
The heater must not be installed directly below a permanently 
installed  socket.  Combustible  materials  or  liquids  and  other 
highly  flammable furnishings must be  kept away from the 
heater.  
For the necessary minimum distances (in mm), see fig. 4. 
Install the device such that  it is not possible  for someone in 
the bath or shower to touch the control elements. 
The heater must not be operated in very dusty areas. 
This device is not suitable for children or persons who cannot 
use the device safely as a result of physical or mental disability 
or  reduced  perception without  the assistance or  supervision 
of  another  person. Children  should  be  supervised  to  ensure 
they do not play with the device. 
A warning symbol is attached to the heater. This in-
dicates that the device must not be covered. 
The operating instructions belong to the device and 
must be stored in a safe place. If the owner changes, the op-
erating instructions should be passed on to the new owner. 
IMPORTANT – If the mains cable of the device is damaged, it 
must  be  replaced  by  the  manufacturer,  a  customer  service 
representative or a similarly qualified person. 
Always ensure proper operation. 
Device description 
The SmartRad model is a fan convector for heating living spaces. 
The fan convector is intended for connection to a central heat-
ing system. The fan convector is suitable for use in heat pump 
systems, but it can also be operated in conjunction with other 
heating systems, e.g. with oil or gas fires. The device draws in air 
from the underside. This is heated up in the heat exchanger and 
discharged at the top. 
Fig. 1: 
(a) Casing cover 
(b) Control panel 
(c) Air outlet guard 
(d) 1 m connection cable 
Fan  convectors  may  only  be used  in  central  heating  systems 
with a closed control circuit. 
The heating system must be operated as a dual-pipe system. 
The  devices  must  be  of  a  sufficient  rating  such  that  they  can 
compensate for heat losses in the room.  
Technical data 
SRX 80
SRX 120
SRX 140
SRX 180
Heat output (kW) at 
flow temperature of 
45°C 
2  0.70  1.10  1.40  1.80 
Temperature range 
of flow temperature (°C) 
  25 – 85 
Maximum permissible 
flow temperature (°C) 
  85 
Permissible operating 
overpressure (MPa) 
  1 
Pressure drop (kPa)
11
.3
13.1
13.7
15.8
Air volume flow (m³/h) 
3
228
345
410
540
2
125
190
225
300
1
60
100
120
160
Sound pressure level at 
1 m (dB(A)) 
3
47
2
38
1
27
Nominal voltage
~ 230 V, 50 Hz
Power consumption  
of fan (W) 
3
26
43
56
50
2
19
29
36
33
1
16
20
24
23
Standby energy
consumption (W) 
  < 1 
Protection category
IP 20
Volume of 
heat exchanger (ml) 
  310  430  480  600 
Dimensions 
W x H x D (mm) 
503 x 
530 x 
145 
670 x 
530 x 
145 
740 x 
530 x 
145 
911 x 
530 x 
145 
Weight (kg)
12
15
17.5
22
Installation preparation 
Remove packaging material.  
Unscrew the four  fixing  screws  from underside  of  device (see 
fig.  2) to remove casing  cover. Store  casing  cover such that it 
cannot be damaged during installation. 
Fixing to the wall 
For drywalls, use suitable fixing material (not supplied)! 
Draw and drill four holes on a sturdy wall as shown in fig. 4. All 
dimensions are in mm. 
Insert dowels and pre-fit the two top screws (don't completely 
screw in yet). 
Hang device on the two top screws. 
Insert and tighten the two bottom screws, then tighten the two 
top screws. 
Hydraulic connection 
To ensure a sufficient heating water flow rate through the fan 
convectors, observe the following points: 
-  The  devices  are  not  suitable  for  installation  in  single-pipe 
systems. 
-  The nominal width of the connection pipe must have a 
minimum diameter of 15 mm. 
-  If the devices are installed in a heating system with various 
heat  distribution systems (e.g. underfloor  heating), a sepa-
rate circuit is required to guarantee a sufficient water flow 
rate. 
-  For optimum operation (heat output) of the fan convectors, 
EN