Technical data
SOLC220 - Free standing kit
Page 10 of 20
ST0117 – C 08/09
SOLAR
6 Installation
Step 1.1 Fixing
- Determine the dimensions of the whole
collector array and mark the position of
the U-pieces (3.1).
- Distance A applies to the spacing be-
tween the U-pieces of the basic kit, dis-
tance D to all extension kits.
- Dimension B relates to the distance
between the U-pieces of adjacent col-
lectors.
- Dimension C is fixed at 1140mm.
- The measurements relate to the middle
of the U-piece components.
- It is important to remember when in-
stalling the collectors, they must be in-
stalled from left to right only, (when
facing the array from surface exposed
to the sun).
Step 1.2 Fixing
- Before drilling the holes in the surface
for the U-pieces, check the spacing
using the diagonals.
- Diagonals E and F must be of equal
length, as must diagonals G an H.
- Next, drill with the ø10 mm drill bit at
the marked positions.
- If drilling is not permitted on a flat
roof due to the leak-tightness of the
roof, appropriate concrete slabs or a
similar material must be used as a
foundation.