Sole/WasserWärmepumpe für Innenaufstellung Installation and Operating Instructions English Instructions d’installation et d’utilisation Français Montage- und Gebrauchsanweisung Brine-to-Water Heat Pump for Indoor Installation Bestell-Nr. / Order no. / No de commande : 452234.66.
Table of contents 1 Read immediately..........................................................................................................................E-2 1.1 Important Information.............................................................................................................................. E-2 1.2 Legal Provisions and Guidelines ............................................................................................................ E-2 1.3 Energy-Efficient Use of the Heat Pump ..
1 1 Read immediately 1.1 Important Information ATTENTION! Any work on the heat pump may only be performed by an authorised and qualified customer service. ATTENTION! The heat pump must not be tilted more than max. 45° (in either direction). English ATTENTION! 1.3 Energy-Efficient Use of the Heat Pump By operating this heat pump you contribute to the protection of our environment.
5 Baseline Unit 4 The baseline unit consists of a heat pump, ready for connection, for indoor installation, complete with sheet metal cabinet, control box and integrated controller. The refrigeration cycle contains the refrigerant R404A. Refrigerant R404A is CFC-free, non-ozone depleting and non-combustible. All components required for the operation of the heat pump are located in the control box.
6 6 Installation 6.1 General Information As a rule, the unit must be installed indoors on a level, smooth and horizontal surface. The entire base frame should make full contact with the surface in order to ensure adequate sound insulation. Failing this, additional sound insulation measures may become necessary. English The heat pump should be installed to allow easy maintenance/ service access. This is ensured if a clearance of approx. 1 m in front of the heat pump is maintained.
8.3 An automatic circuit-breaker with simultaneous tripping of all external conductors is to be provided in the load power supply. The circuit-breaker must be an all-pole disconnect device with a contact gap of at least 3 mm. The same applies to any additional disable contactors that may be required, e.g. during shut-off periods imposed by the utility company.
9 9 Care/Cleaning 9.1 Care The heat pump is maintenance-free. To prevent malfunctions due to sediments in the heat exchangers, care must be taken that no im-purities can enter the heat source system and the heating installation. In the event that operating malfunctions due to contamination occur nevertheless, the system should be cleaned as described below. English 9.
12 12 Equipment Data Type and order code SI 24TE 2 Design 2.1 Degree of protection according to EN 60 529 2.2 Installation location 3 Performance data 3.1 Operating temperature limits: IP 21 IP 21 Indoors Indoors Heating water flow °C up to 60 up to 60 Brine (heat source) °C -5 to +25 -5 to +25 Monoethylene glycol Monoethylene glycol Antifreeze Minimum brine concentration (-13 °C freezing temperature) 3.2 Temperature spread of heating water (flow/return flow) at B0 / W35K 3.
Anhang / Appendix / Annexes 1 Maßbilder / Dimensioned drawings / Schémas cotés............................................................... A-II 1.1 Maßbild / Dimensioned drawing / Schéma coté SI 24TE ....................................................................... A-II 1.2 Maßbild / Dimensioned drawing / Schéma coté SI 37TE ...................................................................... A-III 2 Diagramme / Schematics / Diagrammes ..........................................................
1 1 Maßbilder / Dimensioned drawings / Schémas cotés 1.
1.2 1.
2 2 Diagramme / Schematics / Diagrammes 2.
2.2 2.
3 3 Stromlaufpläne / Wiring diagrams / Schémas électriques 3.
1HW] Â 0DLQV V\VWHP Â 5pVHDX Anhang · Appendix · Annexes 0 LVW RSWLRQDO 0 LV RSWLRQDO 0 HQ RSWLRQ 3.2 3.2 Last / Load / Charge www.dimplex.
RGHU Â RU Â RX A-VIII /D IRQFWLRQ GX qPH JpQpUDWHXU GH FKDOHXU SHXW rWUH VpOHFWLRQQpH 7KH IXQFWLRQ RI WKH VXSSO KHDWLQJ V\VWHP FDQ EH VHOHFWHG 'LH )XQNWLRQ GHV WHQ :( LVW ZlKOEDU .RQWDNW RIIHQ :3 JHVSHUUW &RQWDFW RSHQ +3 GLVDEOHG &RQWDFW RXYHUW 3$& EORTXpH qPH HQWUpHH GH FRXSXUH &RQWDFW RXYHUW 3$& EORTXpH QG GLVDEOH LQSXW &RQWDFW RSHQ +3 GLVDEOHG WHU 6SHUUHLQJDQJ .
3.4 A1 Legende / Legend / Légende F4 F5 H5* J1...J18 Drahtbrücke, muss bei Einsatz eines EVU-Sperrschützes entfernt werden Drahtbrücke, muss bei Verwendung des 2. Sperreinganges entfernt werden Drahtbrücke, muss bei Einsatz eines Motorschutzkontaktes, für den Verdichter, entfernt werden Pressostat Niederdruck-Sole Thermostat Warmwasser (alternativ zu R3) Thermostat Schwimmbadwasser Tauchheizkörper Warmwasser 2. Wärmeerzeuger (Heizkessel oder Elektr.
4 4 Hydraulisches Prinzipschema / Hydraulic block diagrams / Schéma hydraulique 4.
4.
5 5 Konformitätserklärung / Declaration of Conformity / Déclaration de conformité Anhang · Appendix · Annexes A-XII
Glen Dimplex Deutschland GmbH Geschäftsbereich Dimplex Am Goldenen Feld 18 D-95326 Kulmbach Irrtümer und Änderungen vorbehalten. Subject to alterations and errors. Sous réserve d’erreurs et modifications. +49 (0) 9221 709 565 www.dimplex.