Owner’s Manual Revillusion™ Built-in Electric Firebox Revillusion 30" Firebox Revillusion 36" Firebox Revillusion 42" Firebox (RBF30C-AU) (RBF36C-AU) (RBF42C-AU) IMPORTANT SAFETY INFORMATION: Read this manual first before attempting to install or use the Revillusion™ Built-in Electric Firebox. Always comply with the warnings and safety instructions contained in this manual to prevent personal injury or property damage.
Table of Contents Welcome...............................................................3 IMPORTANT INSTRUCTIONS............................. 4 Specifications....................................................... 6 Installation............................................................. 7 Operation...............................................................9 Maintenance.......................................................
Welcome Thank you for purchasing a Revillusion™ Built-in Electric Firebox by Dimplex. Rating Label CAUTION: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible electric shock or fire hazard and will void the warranty. NO NEED TO RETURN TO THE STORE Questions with operation or assembly? Require Parts Information? Product Under Manufacturer’s Warranty? Please consult your warrenty card for our contact details.
IMPORTANT INSTRUCTIONS Read all instructions before using this appliance. When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electrical shock and injury to persons, including the following: 1. If the appliance is damaged, check with the supplier before installation and operation. 2. Do not use outdoors. 3. Do not use in the immediate surroundings of a bath, shower or swimming pool. 4.
IMPORTANT INSTRUCTIONS WARNING: In order to avoid overheating, do not cover the appliance. Do not place material or garments on the appliance, or obstruct the air circulation around the appliance, for instance by curtains or furniture, as this could cause overheating and a fire risk.
Specifications The Revillusion™ Built-in Electric Firebox offers an alternative to a wood or gas fireplace. It can give your existing fireplace new life or transform a cabinet or media center of your own into a stunning focal point.
Installation Framing 1. The RevillusionTM Built-in Electric 2. Firebox does not require any special venting. Rough in the framing opening. Following the recommended framing dimensions below. ! NOTE: The materials used for the finished surround must be cut to precise dimensions (dimensions B & C) as the 1/4" (0.6 cm) self trimming flange is only to create a finished appearance.
Installation Placement Fixed Wiring This firebox is a zero clearance design, with the exception of the top of the unit, where any insulation and vapor barrier should be placed a minimum of 2” (5.1 cm) from the firebox. In some jurisdictions this appliance is supplied without a plug this is to comply with the local regulations.
Operation Touch Panel and Remote Controls WARNING: The RevillusionTM Built-in Electric Firebox must be installed properly before it is used. CAUTION: Except for installation and cleaning described in this manual, an authorized service representative should perform any other servicing. The manual controls for the RevillusionTM Built-in Electric Firebox are located on the front panel. Touch an icon to activate. The selected setting displays on the left side of the panel.
Operation Icon Function Description Press to activate the current standby state (On/Off). • Standby State On Press to turn everything Off. Press again to activate the previous state. A Power/ Standby • Standby State Off Press to activate the previous state. - If the flame effect was On, the previous heat setting will be activated (On or Off). - If the flame effect was Off, the previous heat setting will be activated (High or Low). Press again to turn everything Off.
Operation Icon E F Function Color Themes 360o Light Description Press multiple times to change the flame base colors from Red to Blue to Off. (The first segment on the display will change from "r" to "b" to blank) This feature is active only when the flame effect is On. Press multiple times to change the LEDs on the sides and back of the unit from Midnight mode to white to yellow to red. (The middle segment on the display will change through 0 - 3 respectively.
Maintenance General Maintenance Inspect the built-in electric firebox regularly, depending upon conditions, and at a minimum yearly intervals. Remove dust and clean the logs, grate, and base as required. WARNING: Disconnect power and allow heater to cool before attempting any maintenance or cleaning to reduce the risk of fire, electric shock, or injury. CAUTION: Except for installation and cleaning described in this manual, an authorized service representative should perform any other servicing.