Operating instructions
- 11 -
Bricks
The bricks are supplied separately to the heater in 
packs of three.
The reference number is 047243.
12. The bricks have several grooves on one 
surface for locating around the elements. The two 
slots through the centre of the brick create the air 
passages within the core.
Position the fi rst brick of the bottom row to the right, 
fi rmly pressed against the side insulation with the 
element grooves facing upwards and fi tting neatly 
around the element. Angle the element upward to fi t 
the brick.
DO NOT DISCONNECT THE ELEMENT 
TERMINALS
In addition ensure the slots for the air passages line 
up with the holes in the base insulation. 
Fit the remaining bricks to the bottom row, being 
careful not to damage or dislodge the element.
Note - The bends in the element locate around 
the grooves in the brick to secure the element.
13. Position the second row of bricks on top of 
the fi rst but this time the bricks must be upside 
down ensuring the grooves are positioned over the 
elements.
Fig. 12
Fig. 13
F
i
g
.
1
2