Instructions / Assembly

10 www.dimplex.com
Recessed Installation
Installation
Electrical Cover
1. Remove the side cover panels from the replace by
removing the 5 screws on each of the cover panels
(4 on the back of the replace, 1 on the bottom).
(Figure2)
2. If a trimless installation is desired, remove pre-
installed trim by removing the screws (number of
screws will vary by model). (Figure 3)
!
NOTE: The pre-installed trim helps conceal
imperfections in the drywall edges against
the replace and gives the replace a nished
appearance.
3. Prepare a framed opening, following the dimensions in
the table below. (Figure 4)
Framing Dimensions
Model
Width Height
Depth*
(mininum)
A B C
PLF3614-XS
37"
940 mm
19
1
/
8
"
486 mm
4"
102 mm
* Includes
½" drywall
PLF4214-XS
43"
1092 mm
PLF5014-XS
51"
1295 mm
PLF6014-XS
61"
1549 mm
CAUTION: This replace is NOT load-bearing. Ensure
the opening for the replace is framed in such a way
that the weight of the building materials will not create
pressure on the top of the replace.
!
NOTE: Wiring is performed at the bottom right back
corner of the rebox. (Figure 5) Plan the framing to
allow routing the power cable to this location.
4. Install and nish drywall as desired.
5. Remove the 3 screws that secure the electrical cover
to complete the wiring. (Figure 5)
6. Complete the wiring according to instructions in the
Electrical Installation section (pp. 12-13). Reinstall the
electrical cover after wiring is complete.
7. Lift the rebox into the opening in the framing.
8. Level the rebox. A bubble level is included in the
hardware kit provided.