Warranty

9
Fireplace Installation
For 120V Installations
Use two conductor, non-metallic
sheath cable with ground wire (3
wires total) for the incoming power
supply.
CAUTION: Use the appropriate
wire to meet local and national
electrical codes for rated power
consumption.
Connect the L1 wire from the unit
to the live wire from the power
supply.
Connect the N and H1 wires from
the unit to the neutral wire from
the power supply.
Connect the L2 and H2 wires
together, with a wire connector
and leave them disconnected
from everything.
Attach the grounding wire to
the cover with the provided
grounding screw. Place wire in-
between screw and lock washer
and tighten (Figure 4).
Reposition the electrical cover
brackets over the wires and
connectors and attach to
replace chassis using the screw
removed in step 1 and step 3.
Figure 4
Hole for
Ground Screw
Figure 3