7.1 Operation
The heat pump manager is operated using 6 keys: ESC,
MODUS, MENUE,
, , . Different functions are assigned to
these buttons according to the current display (Standard or
Menu).
The operating status of the heat pump and the heating sys-
tem is indicated in plain text on a 4 x 20 character LC display
(see Fig. 7.1 on page 75).
Six different operating modes can be selected:
Cooling, Summer, Auto, Party, Vacation, 2nd heat
generator.
The menu is made up of three main levels:
Settings, Operating data, History
(see Table 7.3 on page 81).
Fig. 7.1: Heat pump manager WPM 2007 or WPM Econ Plus with dropped standard LC display with operator buttons
NOTE
The contrast of the display can be brightened with the key combination
(ESC), (MODUS), and () or darkened with (ESC), (MODUS), and () All
three keys must be pressed and held together until the required contrast
level is set.
Keyboard block, child lock
To activate the keyboard block, press and hold the (ESC) key for approx-
imately five seconds. When activated, the keyboard block symbol ap-
pears on the display. To release the keyboard block, press and hold the
(ESC) key for approximately five seconds.
Fig. 7.2: Heat pump manager WPM 2006 with integrated standard LC display with operator buttons
Table 7.1: Symbol display (from software version L07)
Other heat generators
shown as symbols,
see table 4.1
Active
lowering
Active
raise
Operator
buttons
Heating warmer / colder
(indicator bar line 4)
Status display HP
(line 1,2,3)
4x20 character display;
back-lit
Operating mode
symbols
[FKDUDFWHUGLVSOD\
EDFNOLW
2SHUDWLQJPRGH
V\PEROV
2SHUDWRUEXWWRQV
+3VWDWXVGLVSOD\
/LQH
+HDWLQJKRWWHUFROGHU
,QGLFDWRUEDUOLQH
2WKHUKHDWJHQHUDWRUV
VKRZQDVV\PEROV
VHHWDEOH
Pipe heater
Immersion heater
Oil boiler
Flange heater
Supplementary heating