Technical data

26 | Project planning manual for heat pumps for heating and domestic hot water preparation | 01.2012 www.dimplex.de
2.3.7.1 Air-to-water heat pumps
The air duct construction kit LKL ..A (see Fig. 2.14 on page 25) is
made up of side walls made from glass fiber reinforced concrete
incl. adhesive and two cover frames. It is not delivered pre-as-
sembled and must be assembled on-site. This means that the air
duct can be transported easily and shortened to the desired
length on-site.
Benefits construction kit LKL ..A
Low risk of damage during transport
Construction kit can be shortened to the desired length eas-
ily on-site
Cover frame enables quick and easy
assembly
2.3.7.1 Dimensions of the wall openings when using lightweight cement based fibre glass air ducts
Fig. 2.15: Front view 600-800
Fig. 2.16: Front view LI 9TU, LI 12TU and LI 15TE
Fig. 2.17: Front view 900
Fig. 2.18: Side view LI 9TU, LI 12TU and LI 15TE
Table 2.8: Table of dimensions heat pump with buffer tank
:DWHUGUDLQ &RQGHQVDWHGUDLQ
2SHUDWRUVLGH
,QVXODWLQJVWULSV
'LUHFWLRQRI
DLUIORZ
%XIIHUWDQN
0LQLPXPURRPKHLJKW&
'HYLFHKHLJKW+
6XSSRUWLQJIHHWDSSUR[
,QVXODWLQJVWULSVDSSUR[

PD[
%
$
$ %
+
' (
Type Heat pump
A (in mm)
with
buffer
A (in mm)
without
buffer
B
(in mm)
D (in mm)
with
buffer
D (in mm)
without
buffer
E
(in mm)
C
(in mm)
H (in mm)
with
buffer
H (in mm)
without
buffer
600 LI 11ME / LI 11TES 1,282 672 650 - - - 2,200 1,981 1,371
700 LI 16TES / LI 20TE 1,340 730 745 - - - 2,400 2,191 1,581
600/800
LI 9TU / LI 12TU /
LI 15TE
1,430 822 600 1,339 730 769 2,400 2,164 1,556