Technical data

www.dimplex.de 01.2012 | Project planning manual for heat pumps for heating and domestic hot water preparation | 127
Integration of the heat pump in the heating system 8.15.9
8.15.9 Swimming pool water preparation
Renewable back-up via a combo tank
Pre-configuration
Setting
Fig. 8.53: Integration diagram for heat pump for bivalent renewable heat pump operation with external back-up domestic hot
water preparation and heating using a combo tank without separating plate
Operating mode
electric heating
Immer-
sion
heater
in the
buffer
1st heating circuit Heating
2nd heating circuit No
Domestic hot water Yes
Flange heater No
Swimming pool No
Note:
The possible domestic hot water
temperatures depend largely on
the design of the combo tank.
On combo tanks without a sepa-
rating plate, the additional buffer
tank (3) guarantees the defrost-
ing function with air-to-water
heat pumps.
A sensor in the bottom section of
the combo tank blocks the heat
pump when it is fully loaded and
activates the mixer regulation.
The water in the combo tank is
heated by solar energy and is
also used for supplementary
heating (see also Chapt. 8.11.3
on page 111).
Heating, domestic hot water and swimming pool water preparation
Pre-configuration
Setting
Fig. 8.54: Integration diagram for mono energy heat pump operation with two heating circuits, domestic hot water and swim-
ming pool water preparation
Operating mode
electric heating
Immer-
sion
heater
in the
buffer
1st heating circuit Heating
2nd heating circuit Heating
3rd heating circuit No
Domestic hot water Yes
Flange heater Yes
Swimming pool Yes
Order of priority:
Domestic hot water preparation
has priority over heating and
swimming pool preparation (see
Chapt. 8.12 on page 111)
A request for swimming pool
water comes in via input ID2.
N1-B1
(R1)
T
(X2-M13)
M13
WWM
DDV
T
3
(X2-K20)
E10.1
(X2-K21)
E9
R3
(X3-R3)
(X2-M18)
M18
(X3-2.1)
R2.1
M16
(X2-M16)
SOLPU
T
(X3-R23)
E1
0
.
5
R23
(X2-M23)
M23
00431094
T
TC
M
R22
(X3-R22)
T
(N1-N07/N08)
M21
3.1
X
16
N1
N17.4
1
R13
(X3-R13)
T
DDV
00232025
R1
(X3-R1)
(X2-M18)
M18
R3
(X3-R3)
(N1-N011)
M15
(X3-R5)
R5
(N1-N012/N013)
M22
T
(X2-M13)
M13
WWM
MMH
VTB
T
T
M16
(X2-M16)
TC
TC
M
R2.1
(X3-R2.1)
T
4
3
(X2-K20)
E10.1
E9
(X2-K21)
B
A
(SWT)
N1-ID2
M19
N1
1