Technical data
118 | Project planning manual for heat pumps for heating and domestic hot water preparation | 01.2012 www.dimplex.de
8.15.4 Integration of the heat pump in the heating system
8.15.4 Heat pumps with hydro tower HWK 332
Mono energy heat pump heating system with one heating circuit
Pre-configuration
Setting
Fig. 8.37: Integration diagram for an air-to-water heat pump installed outdoors with hydro tower HWK 332 Econ
Operating mode
electric heating
Pipe
heater
Heating
1st heating circuit Heating
2nd heating circuit No
Domestic hot water
Yes
with a
sensor
Flange heater Yes
Swimming pool No
The hydro tower with integrated
WPM EconPlus regulation ena-
bles the fast and simple connec-
tion of a high-efficiency air-to-
water heat pump installed out-
doors to a heating system with
an unmixed heating circuit. The
following components are in-
stalled in a space-saving way
and wired ready for use:
a 100l buffer tank, a 300l do-
mestic hot water cylinder, a cir-
culating pump for the generator
circuit (M16), an electronically
regulated circulating pump for
the consumer circuit (M13), a
domestic hot water circulating
pump (M18) and switchable
supplementary heating (2, 4,
6kW).
Bivalent heat pump system with supplementary boiler
Pre-configuration
Setting
Fig. 8.38: Integration diagram for a bivalent operating mode with boiler and hydro tower HWK 332 Econ
Operating mode
Bivalent
heat
pump +
boiler
1st heating circuit Heating
2nd heating circuit No
Domestic hot water
Yes
with a
sensor
Flange heater Yes
Swimming pool No
Hydraulic decoupling of the gen-
erator and consumer circuits is
carried out using a dual differen-
tial pressureless manifold
(Chapt. 8.3.5 on page 97).
TC
T
(X3-B1)
R1
10251034
17
T
R2
M16
M13
E10.1
M18
N1
1.1
E10.2
(X3-R1)
R1
T
TC
(N1-N07/N08)
M21
(X2-K21)
10351034
1.1
M
17
T
R2.1
M16
M13
E10.1
M18
N1