Technical data

www.dimplex.de/en
77
2010
Connection voltage 3/N/PE ~400 V, 50 Hz
PERMATHERM® storage heaters
Hearth design can be integrated
ESK ... K with EZK ES
Hearth design can be panelled with solid kitchen panelling
High-grade hard-shell core thermal insulation of natural
vermiculite with Microtherm®
D ynamic discharge
Thermomechanical AC charge controller
AC control system 230V AC, 80 % operating time
built-in room temperature controller
ON/OFF switch for “supplementary heating”
Temperature lowering at night can be remote controlled
e.g. using a timer.
Control panel kitchen white, base grey-brown
Delivery form: casing, brick bundles and radiator kit
VDE approval mark
Order reference Art.-Nr. Rated power
W
Number of brick
bundles
Brick bundle
type
Size Width x Height
x Depth
mm
Weight
kg
ESK 2419 K IC251318
1900
2 Kolli 33 H 24E 450 x 840 x 570 110
ESK 2424 K IC251320
2400
Height adjustable
ESK 2419 K IC251318 4021481259455
ESK 2424 K IC251320 4021481259448
Storage heaters
Accessories
Supplementary kit – hearth storage heater in free-standing
VKE 20
Supplementary kit for converting the built-under unit to a stand-alone unit consisting of: front cover, worktop, fixing accessories
(worktop height: 40 mm), colour kitchen white.
Order reference Art.-Nr. for device type
VKE 20 317820
VKD 24
EZK ES IC251314
ESK 24.. K
VKE 20 317820 4015627317826
EZK ES IC251314 4021481001306
Two-circuit cylinder kit
GH 18
With the basic device GH 18 the devices FSD 12C – FSD 36C and VKD 24 can be upgraded to two-circuit storage heaters.
With this, the two-circuit system for required for controlled storage heating (GEH) by the EnBW / ODR is made possible.
Key solution:
2/3 of the rated power is switched as P
S
(storage part) and 1/3 of the rated power as P
SF
(storage-free part).
Order reference Art.-Nr. for device type
GH 18 325100
VKD 24
FSD 12C – FSD 36C
GH 18 325100 4015627325104
Supplementary kit two-circuit storage heater
ESF ZKM
for PERMATHERM® Optima (flat design) F 12E – F 36E and PERMATHERM® hearth storage heater for converting to two-circuit system
for controlled electric heating GEH (charge type of the EnBW/ODR).
Order reference Art.-Nr. for device type
ESF ZKM IC260600
ESF 12.. K – ESF 36.. K
ESK 24.. K
ESF ZKM IC260600 4021481260604