Technical data

www.dimplex.de/en
60
2010
Heat pump – air / waste heat as a heat source
Hot-water temp. up to max. 60 °C
Lower operating limit heat source (heating operation) 8 °C
Upper operating limit heat source (heating operation) 35 °C
Hot water heat pump with sheet-steel casing
Air duct connection and additional heat exchanger
AWP 30HLW
High-grade painted sheet steel casing, radial fan, exhaust air stub and outgoing air stub for optional connection of a duct system with a
maximum length of 10 m, infinitely adjustable hot water temperature for total volume of 290 l, switches for heat pump, heating element
and second heat generator, steel cylinder enamelled acc. to DIN 4753, protection anode against corrosion, medium heat pump output
1870 W, hot water temperature selectable during heat pump operation (23° to 60 °C), heating up to 65 °C with standard heating element
(1. 5 kW) possible, can be either manually controlled or, e. g. , via an external timer, integrated additional heat exchanger (approx.
1. 45 m² ) for connecting an external heat generator (e. g. , boiler or solar installation), cladding tube for external cylinder sensor, connec-
tion option for an external block of heat pump operation, relay output for controlling an external loading pump, refrigerant designation
R 134a, colour white (similar to RAL 9003).
Order reference Art.-Nr. Connection voltage COP according to EN 255
for heating up from 15 °C
to 45 °C
Width x Height x Depth
mm
Weight
kg
AWP 30HLW 351390
1/N/PE ~230 V, 50 Hz 3.5 660 x 1700 x 700 175
Nipple size DN 160, connection with SF R 162510 air hose or MFE 16 bush
The maximum hot water temperature reachable and the lower operating limit vary b
y +/- 2K due to component tolerances! In order to prevent
an air short circuit, a room height of approx. 2. 5 m is necessary for free blowing-out mounting. The minimum height of the installation room is
reduced to approx. 2m by using a pipe bend on the air outlet side or by using a connection to an air duct system.
AWP 30HLW 351390 4015627351394
Special accessories for hot water heat pumps
BGN ...
Order reference Art.-Nr. Short text Features Weight
kg
SVK 852 326660
Safety valve combination
For the cold water connection of drinking water
cylinders to the supply network according to DIN 1988;
connection 1 external thread.
1.5
SF R 162510 359620
Sonoflex pipe
Flexible round aluminium ventilation tube, 4 layers,
with 25 mm thermal insulation and vapour block
6.1
SF SD 165015 360780
Sound damper
Flexible sound damper, 4 layers, with thermal insulation
and vapour block
0.7
BGN 16-90 341340
Bend (160mm, 90°)
Bend, pressed, smooth sheet steel, acc. to DIN 24145,
lip seal.
1 .0
MFE 16 341320
Sleeve DN 160
Installation between moulded parts DN 160, smooth sheet
steel, acc. to DIN 24145.
0.2
SVK 852 326660 4015627326668
SF R 162510 359620 4015627359628
SF SD 165015 360780 4015627360785
BGN 16-90 341340 4015627341340
MFE 16 341320 4015627341326
Hot water heat pumps – heat source indoor air / exhaust air
Hot-water temp. up to max. 60 °C
Lower operating limit heat source (heating operation) 15 °C
Upper operating limit heat source (heating operation) 35 °C
Hot water heat pump with foil cladding
for utilisation of indoor air
BWP 20A
Hot water heat pumps for using 20 °C indoor air for domestic hot water preparation, installation dimension 60 cm; Insulated foil cladding,
radial fan, exhaust air stub and outgoing air stub for optional connection of a duct system with a maximum length of 10 m, infinitely
adjustable hot water temperature for total volume of 200 l, switch for permanent fan operation, steel cylinder enamelled according to
DIN 4753, protection anode against corrosion, medium heat pump output 910 W, hot water temperature selectable during heat pump
operation (23° to 60 °C), heating up to 65 °C possible with standard heating element (1. 5 kW), can be controlled either manually or, for
example, via an external timer, refrigerant designation R134a, colour white (similar to RAL 9003).
Order reference Art.-Nr. Connection voltage COP according to
EN 255 for heating up from
15 °C to 45 °C
Width x Height x Depth
mm
Weight
kg
BWP 20A 358230
1/N/PE ~230 V, 50 Hz 3.26 550 x 1700 x 550 96
DN 125 outgoing air stubs for optional connection to an exhaust air system.
The maximum hot water temperature reachable and the lower operating limit vary b
y +/- 2K due to component tolerances!
BWP 20A 358230 4015627358232
Accessories for DN 125 hot water heat pumps
SF R
Order reference Art.-Nr. Short text Features Weight
kg
SF R 122510 359610
Sonoflex pipe
Flexible round aluminium ventilation tube,
4 layers, with 25 mm thermal insulation and
vapour block
4.4
SF R 122510 359610 4015627359611