Technical data
www.dimplex.de/en
59
2010
Heat pump – air / waste heat as a heat source
Heat pump module – heat source indoor air
Max. flow temperature for heating 65 °C
Air-to-water heat pump
for utilisation of waste heat
LI 2M
A heat pump module for utilisation of waste heat; integrated radial fan, exhaust and outgoing air stubs for optional connection of a duct
system DN 160 (maximum length 10m), infinitely variable return set temperature. The transfer of the generated heat output is done via
an integrated stainless steel heat exchanger (external circulating pump required). Heat output approx. 2 kW at an exhaust air tempera-
ture of 25°C and a heating water outlet temperature of 35°C.
Lower operating limit heat source (heating operation) 0 °C ; Upper operating limit heat source (heating operation) 40 °C ;
Refrigerant R134a ; Connection heating ½ ⬙
Order reference Art.-Nr. Short text Width x Height x Depth
mm
Weight
kg
LI 2M 356330
Heat pump module 450 x 725 x 550 54
LI 2M 356330 4015627356337
Hot water heat pumps – heat source indoor air / cellar air
Hot-water temp. up to max. 60 °C
Lower operating limit heat source (heating operation) 8 °C
Upper operating limit heat source (heating operation) 35 °C
Hot water heat pump with foil cladding
with air duct connection
BWP 30H / BWP 30HLW
Insulated foil cladding, radial fan, exhaust air stub and outgoing air stub for optional connection of a duct system with a maximum
length of 10 m, infinitely adjustable hot water temperature for total volume of 300 l, switches for heat pump and heating element, steel
cylinder enamelled acc. to DIN 4753, protection anode against corrosion, medium heat pump output 1870 W, hot water temperature
selectable during heat pump operation (23° to 60 °C), heating up to 65 °C with standard heating element (1. 5 kW) possible, can be either
manually controlled or, e. g. , via an external timer, refrigerant designation R134A, colour white (similar to RAL 9003).
Order reference Art.-Nr. Connection voltage COP according to
EN 255 for heating up from
15 °C to 45 °C
Width x Height x Depth
mm
Weight
kg
BWP 30H 351960
1/N/PE ~230 V, 50 Hz 3.5 660 x 1695 x 660 110
Nipple size DN 160, connection with SF R 162510 air hose or MFE 16 bush
The maximum hot water temperature reachable and the lower operating limit vary b
y ±2K due to component tolerances! In order to prevent an air
short circuit, a room height of approx. 2. 5 m is necessary for free blowing-out mounting. The minimum height of the installation room is reduced
to approx. 2m by using a pipe bend on the air outlet side or by using a connection to an air duct system.
BWP 30H 351960 4015627351967
Hot-water temp. up to max. 60 °C
Lower operating limit heat source (heating operation) 8 °C
Upper operating limit heat source (heating operation) 35 °C
Hot water heat pump with foil cladding
Air duct connection and additional heat exchanger
BWP 30H / BWP 30HLW
Insulated foil cladding, radial fan, exhaust air stub and outgoing air stub for optional connection of a duct system with a maximum
length of 10 m, infinitely adjustable hot water temperature for usable capacity of 290 l, switches for heat pump, heating element and
second heat generator, steel cylinder enamelled acc. to DIN 4753, protection anode against corrosion, medium heat pump output
1870 W, hot water temperature selectable during heat pump operation (23° to 60 °C), heating up to 65 °C with standard heating element
(1. 5 kW) possible, can be either manually controlled or, e. g. , via an external timer, integrated additional heat exchanger (approx.
1. 45 m² ) for connecting an external heat generator (e. g. , boiler or solar installation), cladding tube for external cylinder sensor, connec-
tion option for an external block of heat pump operation, relay output for controlling an external loading pump, refrigerant designation
R 134a, colour white (similar to RAL 9003).
Order reference Art.-Nr. Connection voltage COP according to
EN 255 for heating up from
15 °C to 45 °C
Width x Height x Depth
mm
Weight
kg
BWP 30HLW 351380
1/N/PE ~230 V, 50 Hz 3.5 660 x 1695 x 660 125
Nipple size DN 160, connection with SF R 162510 air hose or MFE 16 bush
The maximum hot water temperature reachable and the lower operating limit vary b
y ±2K due to component tolerances! In order to prevent an air
short circuit, a room height of approx. 2. 5 m is necessary for free blowing-out mounting. The minimum height of the installation room is reduced
to approx. 2m by using a pipe bend on the air outlet side or by using a connection to an air duct system.
BWP 30HLW 351380 4015627351387