Technical data
www.dimplex.de/en
58
2010
Fan convectors
SmartRad fan convectors
Fan convectors heating
SmartRad
SRX ...M
Smart Rad fan convector with integrated electronic thermostat for mounting on the wall. Manual and automatic operation, maximum
fan level can be preset; automatic regulation of fan level according to heat requirement. Water connection can be on the left or right.
Heating and lowering times as well as frost protection can be individually adjusted using various RX programming cassettes which can
be connected to the device.
Order reference Art.-Nr. Rated power
(35 °C flow /
30 °C return
temperature)
W
Rated power
(45 °C flow /
40 °C return
temperature)
W
Rated power
(55 °C flow /
47 °C return
temperature)
W
Air volume
flow
m³/h
Width x Height x
Depth
mm
Weight
kg
SRX 080 m 359080
358 695 956 125 503 x 530 x 145 13.5
SRX 120M 359090
561 1119 1541 190 670 x 530 x 145 17.0
SRX 140M 359100
631 1329 1828 225 740 x 530 x 145 18 .0
SRX 180 m 359110
893 1760 2424 300 911 x 530 x 145 22 .0
SRX 080 m 359080 5011139359087
SRX 120M 359090 5011139359094
SRX 140M 359100 5011139359100
SRX 180 m 359110 5011139359117
Programming cassette EPX, GFP, SRX convectors
RX PW 1
RX TI RB
HL ..C
Order reference Art.-Nr. Features
RX TI 24 RXTI24
24h programming cassette with LC display, connectable to EPX wall convectors. Four IN and OUT
times freely programmable, lit display, key lock. Where several EPX devices are connected using a
control line, a programming cassette can be used to control these devices simultaneously. Similarly,
devices from the FPE, GPE, GFP, KSE and KLE series can be connected to the control line.
RX PW 1 RXPW1
Weekly programming cassette with LC display, connectable to EPX wall convectors, up to four pro-
grams can be set for a weekend block (Sat-Sun) or a workday block (Mon-Fri), the IN and OUT switch
times are set, with lit display and key lock. Where several EPX devices are connected using a control
line, a programming cassette can be used to control these devices simultaneously. Similarly, devices
from the FPE, GPE, GFP, KSE and KLE series can be connected to the control line.
RX TI RB RXTIRB
Limited specified heating periods; programming cassette for setting a heating period from 0.5 – 4.0
hours, adjustable in 0.5 hour steps, when the specified heating period ends, the device shuts off or
turns to antifreeze mode. Where several EPX devices are connected using a control line, a program-
ming cassette can be used to control these devices simultaneously. Similarly, devices from the FPE,
GPE, GFP, KSE and KLE series can be connected to the control line.
RX TI 24 RXTI24 5011139020673
RX PW 1 RXPW1 5011139020680
RX TI RB RXTIRB 5011139020703
Fan convectors heating/cooling
Casing colour white
Connection voltage 1/N/PE ~230 V, 50 Hz
Fan convectors heating/cooling
with integrated electronic thermostat
Exclusive rounded design; compact dimensions; especially suited for wall mounting; ceiling suspension possible; floor mounting using
special accessories (ZH1). Water connections can be reversed during installation (½“ internal thread connections); adjustable ventilation
grid; the fan convector switches off automatically when the ventilation grid closes; electronic temperature control; automatic speed
change on the ventilator; automatic operating mode switch-over and automatic switch-on/switch-off depending on the flow tempera-
ture; minimum flow temperature of 35 °C for heating operation, maximum of 17 °C for cooling operation; constant-volume water flow;
ventilation unit with radial fan and 3 speed levels; especially low-noise operation; with electronically regulated fan as standard.
Order reference Art.-Nr. Heating
output
35/30 °C
W
Heating
output
50/45 °C
W
Cooling
capacity
7/12 °C
W
Water flow
l/h
Pressure
drop
Pa
Width x Height x
Depth
mm
Weight
kg
HL 11C 351730
510 880 650 111 1170 640 x 507 x 187 13.6
HL 16C 351740
760 1300 950 163 2420 750 x 512 x 189 14.6
HL 26C 351750
1410 2390 1790 307 8555 980 x 522 x 191 17.6
HL 36C 351760
1780 3020 2330 399 6470 1200 x 526 x 198 20.6
By replacing the radiators present in existing buildings with fan convectors, the system temperatures can be lowered thereby increasing the
annual performance factor of the heat pump heating system.
HL 11C 351730 4015627351738
HL 16C 351740 4015627351745
HL 26C 351750 4015627351752
HL 36C 351760 4015627351769
Device base for floor mounting
ZH
Supporting feet for direct floor mounting of the fan convector with the option of feeding through the connecting pipes
(base height: 93 mm); colour white (packaging unit 2).
Order reference Art.-Nr. for device type Weight
kg
ZH 1 351850
HL 11-36C/SK 0.9
ZH 1 351850 4015627351851