Technical data
www.dimplex.de/en
55
2010
Solar station for hot water
Solar back-up for domestic hot water preparation
SST 25
Heat exchanger solar station consisting of solar separation system and pump assembly with insulation jackets for integrating solar
installations up to 10 m² into the DHW heating system. The solar station enables efficient hot water heating via the heat pump as well as
via the solar installation. Modules with primary and secondary cycle consisting of: 2 circulating pumps (WILO- STAR-ST 25/6 and
STAR-RS 24/4); 4 ball valves 1“ with thermometer, return flow inhibitor, safety assembly with safety valve and 0-10 bar pressure gauge,
connection options for expansion vessel (solar controller not included in scope of supply).
Order reference Art.-Nr. Width x Height x Depth
mm
Weight
kg
SST 25 348430
320 x 1050 x 320 19
SST 25 348430 4015627348431
Dirt traps
SMF ..
Dirt trap for installation into the heating circuit, suitable for all non-corrosive substances up to 150°C. To protect the heat pump against
damage caused by impurities and thus extend its service life.Mesh size 0.6 mm.
Order reference Art.-Nr. for device type Connection heating
⬙
Weight
kg
SMF 25 362130
LA 8 – LA 16AS(R)/PS
LI(K)8 – 9TE(L)
1 1.0
SMF 32 362140
LA 17 – 28PS/AS/HS
LI 11 – 28TE(R+)
SI(K/H) 5 – 21
WI 9 – 27
1¼ 1.2
SMF 40 362150
LI 40AS
SI(H) 40 – 50TE
WI 50TU
1½ 1.5
SMF 50 362160
SI 75 – 100TE(R+)
WI 100TU
2 2.3
SMF 65 362170
SI 130TE 2½ 3.7
SMF 25 362130 4015627362130
SMF 32 362140 4015627362147
SMF 40 362150 4015627362154
SMF 50 362160 4015627362161
SMF 65 362170 4015627362178
Expansion joints
KOMP ..
Double-sphere rubber expansion joint for isolating heat pumps and heating systems. Absorbs oscillations and movements caused by
pumps, compressors, fittings and other sources, reduces noise output and evens out internal strain (axial and lateral deviations) stem-
ming from imprecisions in assembly. EPDM bellows, galvanised C-steel internal thread connections, service temperature -10°C to 110°C.
Order reference Art.-Nr. for device type Connection heating
⬙
Weight
kg
KOMP 25 362050
LA 8 – 16AS(R)/PS
LI(K) 8 – 9TE(L)
1 2.0
KOMP 32 362060
LA 17 – 28PS/AS/HS, LA 9 – 17TU
LI 11 – 28TE(R+)
SI(K/H) 5 – 21
WI 9 – 27
1¼ 2.8
KOMP 40 362070
LA 25 – 40TU
LI 40AS
SI(H) 40 – 50TE
WI 50TU
1½ 4.9
KOMP 50 362080
SI 75 – 100TE(R+)
WI 100TU
2 6.3
The installation of double-sphere rubber expansion joints between the heat pump and the heating system is strongly recommended for solid-
borne sound insulation purposes. The following heat pumps are equipped with integrated solid-borne sound insulation: LA 9 – 60TU, LIKI 14TE,
SI 22TU, SIK(H) compact brine-to-water heat pumps, brine-to-water and water-to-water heat pumps with two performance levels. The installation
of an additional expansion joint is also recommended for these heat pumps, in order to optimise solid-borne sound insulation.
KOMP 25 362050 4015627362055
KOMP 32 362060 4015627362062
KOMP 40 362070 4015627362079
KOMP 50 362080 4015627362086
Accessories for heat pump for heating purposes
Connection set
VSE 32-...
Flexible DN 32 stainless steel Wellflex pipe available in different lengths with 1½“ cap nut, seals and 1½“ external thread – 1¼“ external
thread transitional screw connection for quick and easy connection of heat pump, hot water cylinder and buffer tank to the heat
distribution system.
Order reference Art.-Nr. Connection heating
⬙
Features Weight
kg
VSE 32-50 362520
1 ½
DN 32, length 500 mm 0.9
VSE 32-100 362530
DN 32, length 1000 mm 1.2
VSE 32-150 362540
DN 32, length 1500 mm 2.6
VSE 32-200 362550
DN 32, length 2000 mm 2.7
VSE 32-300 362560
DN 32, length 3000 mm 3.4
VSE 32-50 362520 4015627362529
VSE 32-100 362530 4015627362536
VSE 32-150 362540 4015627362543
VSE 32-200 362550 4015627362550
VSE 32-300 362560 4015627362567