Technical data
www.dimplex.de/en
54
2010
Domestic hot water preparation distribution system modules
WWM 25 with UP ..
VTB 25
Hot water module
Combinable module with insulation jackets for connecting DHW or swimming pool water preparation. Can be used for a heating water
flow rate of up to 2.5 m³/h. Consisting of two ball valves with check valve, two integrated thermometers, pump ball valve, insulation
jackets, installation option for circulating pump, inside micrometer 180 mm, DN 25, which is to be constructed after pressure loss of the
heating system (not included in the scope of supply).
Manifold bar
Combinable module with insulation jackets for connecting to a KPV 25 compact manifold and WWM 25 hot water module. Each with
two connecting pairs 1 ½“ (external thread/internal thread) upwards and downwards, useable for a hot water flow of up to max. 2.5 m³/h
(flat sealing).
Order reference Art.-Nr. Short text Width x Height x
Depth
mm
Weight
kg
WWM 25 346600
Hot water module / unmixed heating circuit module 245 x 420 x 240 3.9
VTB 25 339870
Manifold bar 500 x 180 x 135 7.1
WWM 25 346600 4015627346604
VTB 25 339870 4015627339873
Hot water pump unit
WPG 32
Pump unit for direct mounting of the hot water circulating pump on the rear of the hot water cylinder (pump not included in the scope
of supply). Consisting of: Elbow union with manual bleeders, installation option for DN 25 circulating pump with two ball valves and
gravity control.Extra WPG 32:1¼“ elbow union with drainage for hot water return.
Order reference Art.-Nr. for device type Connection heating
⬙
Weight
kg
WPG 25 356030
UP 60
UP 80
1¼ 1.9
WPG 32 356040
UP 60-32
UP 70-32
1½ 4.4
WPG 25 356030 4015627356030
WPG 32 356040 4015627356047
Circulating pumps for DHW preparation
UP 80
Unregulated circulating pump, applicable for the hot water load circuit, inner micrometer 180 mm.
Order reference Art.-Nr. Nominal width Features Weight
kg
UP 60 340300
DN 25
Delivery height max. 3,5 m at a volume flow of 2 m³/h.
2.4
UP 60-32 355970
DN 32 2.6
UP 80 340310
DN 25 Delivery height max. 4 m at a volume flow of 5 m³/h. 4.5
The reachable hot water temperatures are dependent on the maximum heat output of the heat pump, the heat exchanger area and the volume
flow in the load circuit (the respective design for a maximum hot water temperature of 45 °C according to the project planning documentation).
For heat pumps with two performance levels, the DHW preparation can be done using a compressor.
UP 60 340300 4015627340305
UP 60-32 355970 4015627355972
UP 80 340310 4015627340312
Mixer module for bivalent systems
MMB 25
Combinable mixer module for connecting a second heat generator (e.g. oil boiler) or a renewable heat generator with heat accumulator.
Can be used for a heating water flow rate of up to 2 m³/h. Consisting of a 4-way mixer with actuator and 140 sec. runtime, connection
voltage ~230 V, degree of protection IP40.
Order reference Art.-Nr. Width x Height x Depth
mm
Weight
kg
MMB 25 348880
190 x 365 x 160 5.3
MMB 25 348880 4015627348882
Accessories for heat pump for heating purposes