Technical data

www.dimplex.de/en
53
2010
Electronic circulating pump for consumer circuit
UPE 60
Electronically controlled circulating pump UPE 60
Electronically-controlled heat circulating pump with integrated flexible capacity via freely-adjustable rotational speed, micrometer
180 mm, low energy consumption thanks to energy efficiency class A (fulfils the requirements of EnEV, §14 (3)), automatic lowering of
temperature at night, type of regulation (controlled or constant rotational speed) and the control curve can be set automatically via
Softtouch, including pump plug for easy installation of the electrical connection cable.
Electronically controlled circulating pumps UPE 70, UPE 80, UPE 120
High-efficiency wet running pump with integrated electronic power regulation. Types of regulation selectable via operating button for
optimum load adjustment (differential pressure regulation constant (∆p-c) or variable (∆p-v) and speed adjustment via control input).
Low energy consumption thanks to energy efficiency class A (complies with the requirements of the EnEV, §14 (3)), inside micrometer
180 mm, including mains and control cable (length 1.5 m). Relay for decoupling the control and load circuits, including relay base and
retaining clip in the scope of supply.
Order reference Art.-Nr. Nominal width Features Weight
kg
UPE 60 358870
2 5
Maximum delivery height 3.2 m at a volume flow of 2 m
3
/h 2.3
UPE 70-25 362790
Maximum delivery height 5.9 m at a volume flow of 2 m
3
/h
2.8
UPE 70-32 362800
3 2 3.0
UPE 80-25 362810
2 5
Maximum delivery height 5.2 m at a volume flow of 5 m
3
/h 4.2
UPE 80-32 362820
3 2
UPE 120-32 362830
Maximum delivery height 8.5 m at a volume flow of 7 m
3
/h 6.5
The use of an electronically-regulated circulating pump in the consumer circuit requires a manifold without differential pressure. An unregulated
circulating pump must be used in the main heat pump circuit in order to ensure the minimum heating water flow rate.
Pump dimensioning must be checked according to the pressure drop and volume flow!
UPE 60 358870 4015627358874
UPE 70-25 362790 4015627362796
UPE 70-32 362800 4015627362802
UPE 80-25 362810 4015627362819
UPE 80-32 362820 4015627362826
UPE 120-32 362830 4015627362833
Heating distribution system modules
WWM 25 with UP ..
MMH 25 with UP ..
VTB 25
Unmixed heating circuit module
Combinable module with insulation jackets for connecting an unmixed heating circuit or DHW or swimming pool water preparation.
Can be used for a heating water flow rate of up to 2.5 m³/h. Consisting of two ball valves with check valve, two integrated thermometers,
pump ball valve, insulation jackets, installation option for circulating pump, inside micrometer 180 mm, DN 25 (pump not included in the
scope of supply).
Mixed heating circuit module
Combinable module with insulation jackets for connecting a mixed heating circuit. Can be used for a heating water flow rate of up to
2 m³/h. Consisting of two ball valves with check valve, two thermometers, 3-way mixer with actuator and 140 sec. runtime, connection
voltage ~230 V, degree of protection IP40, strap-on sensor and insulation jackets, installation option for regulated circulating pump,
inside micrometer 180 mm, DN 25, which is to be constructed after pressure loss of the heating system (pump not included in the scope
of supply).
Manifold bar
Combinable module with insulation jackets for simultaneous connection of several heating distribution system modules, with two 1½“
(external/internal thread) connecting pairs each to the top and bottom, universally combinable with KPV 25, MMH 25 and WWM 25,
complete with union and connecting pieces (flat sealing).
Order reference Art.-Nr. Short text Width x Height x
Depth
mm
Weight
kg
WWM 25 346600
Hot water module / unmixed heating circuit module 245 x 420 x 240 3.9
MMH 25 348640
Mixed heating circuit module with temperature sensor 250 x 420 x 250 5 .0
VTB 25 339870
Manifold bar 500 x 180 x 135 7.1
If the hot water distribution system is used for heating and cooling, the water-bearing pipes must have a low-temperature insulation within
the insulation jackets. With reversible heat pumps with additional heat exchanger no manifold bar is necessary for the connection of the DHW
preparation!
WWM 25 346600 4015627346604
MMH 25 348640 4015627348646
VTB 25 339870 4015627339873
Accessories for heat pump for heating purposes