Technical data

www.dimplex.de/en
33
2010
Max. flow temperature for heating 70 °C
Casing colour white
High-temperature brine-to-water heat pump
Universal design with high coefficients of performance
SIH 6TE
Heat pump for indoor installation with integrated regulation WPM 2007 plus. The control panel is integrated into a brown-red design
screen and can also be used as wired remote control using the wall mounting set (special accessories MS PGD). Variable connection
options for brine and heating connections on the rear wall of the casing. Sound-optimised through insulated metal casing and double
vibration-isolated compressor. High COPs through economiser and compliance with the requirements of EN 14511 for larger volume
flows on the heat consumption side. Universal design with optional DHW preparation and the option of flexible expansion for:
Bivalent or bivalent-renewable operating mode
Distribution systems with unmixed and mixed heating circuits
Integrated soft starter and load contactor for brine circulating pump, integrated flow and return flow sensors; external sensor (standard
NTC-2) and dirt filter for brine circuit included in the scope of supply.
Brine package and brine circuit manifold must be ordered separately.
Lower operating limit heat source (heating operation) -5 °C ; Upper operating limit heat source (heating operation) 25 ° C ;
Refrigerant R134a ; Connection heating ; Heat source connection .
Order reference Art.-Nr. Heat output with 1 compressor /
COP B0/W35
Connection voltage Width x Height x
Depth
mm
Weight
kg
SIH 6ME 355170
6.2 / 4.3 (4.1)
1/N/PE ~230 V, 50 Hz
650 x 805 x 462
118
SIH 9ME 355180
9.1 / 4.2 (4.0) 130
SIH 11ME 355190
10.8 / 4.6 (4.5) 133
SIH 6TE 355140
6.2 / 4.6 (4.5)
3/N/PE ~400 V, 50 Hz
118
SIH 9TE 355150
9.0 / 4.5 (4.4) 130
SIH 11TE 355160
11.2 / 4.7 (4.5) 133
Heat output and COP according to EN255 (EN 14511) at B0/W35 (B0 = brine inlet temperature 0 °C, W35 = heating water outlet temperature +35 °C) .
The maximum flow temperatures (up to 70 °C) are available for DHW preparation all year round, and allow DHW temperatures of up to 60 °C to be
achieved without electrical reheating using a flange heater.
SIH 6ME 355170 4015627355170
SIH 9ME 355180 4015627355187
SIH 11ME 355190 4015627355194
SIH 6TE 355140 4015627355149
SIH 9TE 355150 4015627355156
SIH 11TE 355160 4015627355163
Brine-to-water heat pump connection kit
VSH BS
Hose set for connecting a heat pump to the KPV 25 compact manifold or the VTB 25 manifold bar. The set contains two flexible Wellflex
pipes with high-and-low temperature insulation for fast and easy installation (can also be used for connecting the brine circuit).
Order reference Art.-Nr. for device type
VSH BS 347790
SI(H) 5 – SI 17 heating ciruit
SI(H) 5- SI 11 brine circuit
VSH BS 347790 4015627347793
Design built-under buffer tank
PSP 100E
Nominal content 100 l; in brine-to-water heat pump design to enable space-saving installation on top of the built-under buffer tank; po-
lyurethane insulation for minimal downtime losses (can be used for heating and cooling); 1½“ bush for immersion heaters (up to CTHK
635); 1¼“ heating water connections; colour: white; brown red design screen.
Order reference Art.-Nr. Short text for device type Width x Height x
Depth
mm
Weight
kg
PSP 100E 353360
Built-under buffer tank
SIK(H) 7 14
SI(H) 5 – 17
650 x 550 x 653 54
PSP 100E 353360 4015627353367
Design built-under hot water cylinder
WWSP 229E
Nominal capacity 227 l, in brine-to-water heat pump design to enable space-saving installation on the built-under buffer, tube heat
exchanger (internal), steel cylinder (special inside enamelling) with protection anode, polyurethane insulation with minimum stand-by
losses; integrated temperature sensor for connection to the heat pump manager, colour: white, brown red design screen
Permissible operating pressure 10 bar; Flange TK150/DN110 ;
Order reference Art.-Nr. for
device
type
Usable
capacity
l
Heat ex-
changer
surface
area
Con-
nection
heating
Con-
nection
circula-
tion
Connec-
tion hot
water
Width x Height x
Depth
mm
Weight
kg
WWSP 229E 353380
up to
SI(KH) 9
206 2.9 ¾ 1 650 x 1040 x 680 110
Recommended for service areas without shut-off times or with reduced hot water consumption.
Note: A minimum buffer volume of the heating system of 10% of the heating water flow must be ensured either by a buffer tank or other suitable
measures!
WWSP 229E 353380 4015627353381
Heat pump for heating purposes – ground source