Technical data

www.dimplex.de/en
31
2010
Design tank for compact brine-to-water heat pump
Design built-under buffer tank
PSP 100E
Nominal content 100 l; in brine-to-water heat pump design to enable space-saving installation on top of the built-under buffer tank;
polyurethane insulation for minimal downtime losses (can be used for heating and cooling); 1½“ bush for immersion heaters (up to
CTHK 635); 1¼“ heating water connections; colour: white; brown red design screen.
Order reference Art.-Nr. Short text for device type Width x Height x
Depth
mm
Weight
kg
PSP 100E 353360
Built-under buffer tank
SIK(H) 7 14
SI(H) 5 – 17
650 x 550 x 653 54
PSP 100E 353360 4015627353367
Design hot water cylinder
WWSP 442E
Nominal content 400 l, in brine-to-water heat pump design, tube heat exchanger (internal), three supporting feet, steel cylinder (spe-
cial inside enamelling) with protection anode, polyurethane insulation with minimal stand-by losses (approx. 2.7 kWh/24h), integrated
temperature sensor for connection to the heat pump manager, colour white, brown red design screen.
Order reference Art.-Nr. for device
type
Usable
capacity
l
Heat
exchanger
surface
area
Con-
nection
heating
Connec-
tion circu-
lation
Connec-
tion hot
water
Width x Height x
Depth
mm
Weight
kg
WWSP 442E 353370
SIK 7 14
SIKH 6 – 9
SI(H) 20 – 30
353 4.2 ¾ 1 650 x 1660 x 680 187
The reachable hot water temperatures are dependent on the maximum heat output of the heat pump, the heat exchanger area and the volume
flow in the load circuit (the respective design for a maximum hot water temperature of 45 °C according to the project planning documentation).
For heat pumps with two performance levels, the DHW preparation can be done using a compressor.
WWSP 442E 353370 4015627353374
Design built-under hot water cylinder
WWSP 229E
Nominal capacity 227 l, in brine-to-water heat pump design to enable space-saving installation on the built-under buffer, tube heat
exchanger (internal), steel cylinder (special inside enamelling) with protection anode, polyurethane insulation with minimum stand-by
losses; integrated temperature sensor for connection to the heat pump manager, colour: white, brown red design screen
Permissible operating pressure 10 bar; Flange TK150/DN110 ;
Order reference Art.-Nr. for
device
type
Usable
capacity
l
Heat ex-
changer
surface
area
Con-
nection
heating
Con-
nection
circula-
tion
Connec-
tion hot
water
Width x Height x
Depth
mm
Weight
kg
WWSP 229E 353380
up to
SI(KH) 9
206 2.9 ¾ 1 650 x 1040 x 680 110
Recommended for service areas without shut-off times or with reduced hot water consumption.
Note: A minimum buffer volume of the heating system of 10% of the heating water flow must be ensured either by a buffer tank or other suitable
measures!
WWSP 229E 353380 4015627353381
Heat pump for heating purposes – ground source
Compact brine-to-water heat pump connection set
VSH KS
VSW KS
VS PKS
VSW 229
Order reference Art.-Nr. for device
type
Short text Features
VSH KS 343110
SIK(H)
Heating
connection set
Hose set for easy connection of the compact brine-to-water heat
pump and built-under buffer tank to heating system (minimum
distance from wall 20 cm). Consisting of four elbow unions with
three manual air bleeds, buffer connection with filling and drain
cocks and two corrugated stainless steel pipes with high-and-
low temperature insulation. 1
internal thread connection to the
heating system.
VSW KS 343120
VSH KS
with WWSP
Hot water
expansion kit
Hot water extension hose kit, to enable the use of the heating
connection kit (VSH KS) in addition to the hot water cylinder con-
nection and a circulating pump. Consisting of 3 elbow unions with
2 manual air bleeds, 1 tee joint, pump shut-offs for the hot water
circulating pump (pump not included in the scope of supply) and
2 corrugated stainless steel pipes with high-and-low temperature
insulation.
VS PKS 348630
VSH KS
with PKS
Extension
hose kit
for passive
cooling station
Passive cooling station extension hose kit, to enable the use of the
heating connection kit (VSH KS) in addition to the heating and
brine circuit connection of the passive cooling station PKS 14, si-
tuated on the compact brine-to-water heat pump. Consisting of 2
elbow unions with manual air bleeds, crosspiece and 4 corrugated
stainless steel pipes with high-and-low-temperature insulation.
VSW 229 356050
SIK(H)
with
WWSP 229E
Connection set,
hot water
Hose set for easy connection of the compact brine-to-water heat
pump and the built-under hot water cylinder to the heating
systems. Consisting of 2 corrugated stainless steel pipes with
high-and-low temperature insulation, 2 elbow unions with manual
air bleeds and an installation option for the hot water circulating
pump (pump not included in the scope of supply).
VSH KS 343110 4015627343115
VSW KS 343120 4015627343122
VS PKS 348630 4015627348639
VSW 229 356050 4015627356054