Technical data

www.dimplex.de/en
21
2010
Air-to-water heat pump with straight air flow
Max. flow temperature for heating 58 °C
Casing colour white
Low-temperature air-to-water heat pump
Universal design
LI 11/16TE(L)
Heat pump for indoor installation with integrated regulation WPM 2007 plus. The control panel is integrated into a brown-red design
screen and can also be used as wired remote control using the wall mounting set (special accessories MS PGD). The integrated air flow
enables corner or wall installation with air ducts at the air intake and the air outlet side. Sound-optimised through low-noise axial-flow
fan and vibration-isolated compressor. High coefficients of performance using an evaporator optimised for heating operation and ener-
gy-efficient defrosting by reverse circulation. Universal design with optional DHW preparation and the option of flexible expansion for:
Bivalent or bivalent-renewable operating mode
Distribution systems with unmixed and mixed heating circuits
Built-in pipe heater (2 / 4 / 6 kW) (not LI 11ME),
Integrated soft starter, flow and return-flow sensors; external sensor (standard NTC-2) included in the scope of supply.
Lower operating limit heat source (heating operation) -25 °C ; Upper operating limit heat source (heating operation) 35 ° C ;
Refrigerant R404A ; Connection heating
Order reference Art.-Nr. Heat output with
1 compressor /
COP A2/W35
Connection voltage Air outlet Width x Height x
Depth
mm
Weight
kg
LI 11ME 352760
9.1 / 3.4 (3.3) 1/N/PE ~230 V, 50 Hz
right
750 x 1360 x 880
200
LI 11TE 352630
8.8 / 3.2 (3.1)
3/N/PE ~400 V, 50 Hz
LI 11TEL 352640
left 210
LI 16TE 352650
12.2 / 3.2 (3.1)
right
750 x 1570 x 880
235
LI 16TEL 352660
left 245
Heat output and COP according to EN 255 (EN 14511) at A2/W35 (A2 = air intake temperature +2 °C, W35 = heating water outlet temperature +35 °C) .
Delivery times for heat pumps with air output on the left on request!
LI 11ME 352760 4015627352766
LI 11TE 352630 4015627352636
LI 11TEL 352640 4015627352643
LI 16TE 352650 4015627352650
LI 16TEL 352660 4015627352667
Max. flow temperature for heating 58 °C
Flow temperature cooling min. 7 °C
Casing colour white
Reversible air-to-water heat pump
Optimised for heating
LI 11MER
Heat pump for heating and cooling for indoor installation with integrated WPM 2007 R controller. The control panel is integrated into a
brown-red design screen and can also be used as wired remote control using the wall mounting set (special accessories MS PGD). The
integrated air flow enables corner or wall installation with air ducts at the air intake and the air outlet side. Sound-optimised through
low-noise axial-flow fan and vibration-isolated compressor. High coefficients of performance using an evaporator optimised for heating
operation and energy-efficient defrosting by reverse circulation. Universal design with optional DHW preparation and the option of
flexible expansion for:
bivalent operation (bivalent-renewable not possible)
combined distribution systems for heating and cooling
unmixed and mixed heating and cooling circuits
Silent cooling via panel heating/cooling systems requires the use of the room climate control station (special accessory) to regulate the
flow temperature on the basis of the air temperature and humidity of a reference room. Integrated soft starter, flow and return-flow
sensors; external sensor (standard NTC-2) included in the scope of supply.
Lower operating limit heat source (heating operation) -25 °C ; Upper operating limit heat source (heating operation) 35 °C ;
Lower operating limit heat source (cooling operation) 15 °C ; Upper operating limit heat source (cooling operation) 40 °C ;
Refrigerant R404A ; Connection heating ; Connection voltage 1/N/PE ~230 V, 50 Hz
Order reference Art.-Nr. Heat output with 1
compressor / COP
A2/W35
Cooling capacity 1
compressor / EER
A27/W7
Connection heating
Width x Height x
Depth
mm
Weight
kg
LI 11MER 352800
8.9 / 3.4 (3.3) 8.8 / 2.8 750 x 1360 x 880 205
Heat output and COP according to EN 255 (EN 14511) at A2/W35 (A2 = air intake temperature +2 °C, W35 = heating water outlet temperature +35 °C).
Cooling capacity and coefficient of performance according to EN 14511.
LI 11MER 352800 4015627352803
Heat pump for heating – air source – indoor installation