Technical data

www.dimplex.de/en
15
2010
Connection heat pump – heating water connection line
Optimised for connection to a heat pump
VSF ..
Flexible hose connection set, length 250 mm, for fast and simple connection of an air-to-water heat pump (installed outdoors) to a
heating water connection line laid under the ground. Consists of two insulated stainless steel Wellflex pipes with cap nuts and screw
connections.
Order reference Art.-Nr. for device type Connection heating
Features Weight
kg
VSF 25 361790
LA 9 – 17TU
LA 9 – 16AS
LA 9 11PS
1 ¼
Stainless steel Wellflex DN 25 1.4
VSF 32 361800
LA 25TU
LA 20 – 28AS
LA 17 – 26PS
LA 22 26HS
Stainless steel Wellflex DN 32 1.4
VSF 25 361790 4015627361799
VSF 32 361800 4015627361805
House infeeds for heating water connection lines
For pressuring and non-pressuring water
MDM ..
MDF ..
House infeeds as an accessory for HVL 25 and HVL 32 heating water connection lines. The MDM sealing collars, consisting of a protection
tube with shrink hose, are suitable for non-pressuring water (rain water, surface water and leakage water). The MDF sealing flange (stain-
less steel V2A) is suitable for pressuring water (slope water, ground water, plain tracts and water veins).
Order reference Art.-Nr. Short text Features Weight
kg
MDM 145 358890
Wall-sealing collar (protection tube
with shrink hose)
Sealing collar for HVL 25 (cover Ø 145 mm)
as a house infeed (recommended drilling
Ø 220 mm) through brickwork
1.3
MDM 175 358900
Sealing collar for HVL 32 (cover Ø 175 mm)
as a house infeed (recommended drilling
Ø 260 mm) through brickwork
1.5
MDF 145 358910
Wall-sealing flange (stainless steel V2A)
Wall-sealing flange for HVL 25 (cover
Ø 145 mm), sealing width 80 mm, recom-
mended drilling Ø 200 mm
2.3
MDF 175 358920
Wall-sealing flange for HVL 32 (cover
Ø 175 mm), sealing width 80 mm, recom-
mended drilling Ø 250 mm
2.6
For brickwork walls:
So that water cannot penetrate the house infeeds, these must be painted with a bitumen-based protective coating. The house feed-through (MDF)
must additionally be stabilised with a casing tube to seal it against pressuring water.
MDM 145 358890 4015627358898
MDM 175 358900 4015627358904
MDF 145 358910 4015627358911
MDF 175 358920 4015627358928
General installation material
for connecting the heat pump to the heating system
SMF ..
AS ...
TUE ...
SCHT ...
Order reference Art.-Nr. Short text Connection heating
Features Weight
kg
SMF 25 362130
DN 25 dirt trap 1 Mesh size 0.6 mm for LA 8 LA 16AS(R)/PS 1.0
SMF 32 362140
DN 32 dirt trap Mesh size 0.6 mm for LA 17 28PS/AS/HS 1.2
AS 976 322180
1
connecting hose
1
Flexible, compression-proof hose for connec-
ting the heat pump to the heating system,
length 10 m, can be cut to length, without
insulation.
7.0
AS 976-1 330530
1 ¼
connecting
hose
8.5
SCHT 975-1 322250
1
external thread
hose nozzle for 1
connecting hose
1
Hose nozzle with external thread and hose
clip for connecting hose, (for connection to
the heating system e.g. compact manifold).
0.2
SCHT 975-3 322260
1 ¼
external thread
hose nozzle for 1
connecting hose
1 ¼
0.3
SCHT 975-4 330540
1 ¼
external thread
hose nozzle for 1¼
connecting hose
0.3
TUE 430 337430
1
nozzle for 1
connecting hose
1
Nozzle with cap nut (internal thread) for con-
necting hose (for connection to heat pump).
0.2
TUE 440 337440
1 ¼
nozzle for 1¼
connecting hose
0.3
Their allocation to heat pumps and further information concerning the recommended use of the expansion joints can be found in the product
section on heat pump distribution systems.
SMF 25 362130 4015627362130
SMF 32 362140 4015627362147
AS 976 322180 4015627322189
AS 976-1 330530 4015627330535
SCHT 975-1 322250 4015627322257
SCHT 975-3 322260 4015627322264
SCHT 975-4 330540 4015627330542
TUE 430 337430 4015627337435
TUE 440 337440 4015627337442
Heat pump for heating purposes – air source – outdoor installation