Technical data

www.dimplex.de/en
13
2010
Max. flow temperature for heating 65 °C
Casing colour white aluminium
Medium-temperature air-to-water heat pump
for free-standing installation
LA 11PS
Medium-temperature air-to-water heat pumps for outdoor installation with external temperature controlled WPM 2006 plus heat pump
manager. Sound-optimised through the use of noise-reducing crescent wing axial-flow fans and air deflector hoods; energy-efficient hot
gas defrosting. Universal design with optional DHW preparation and the option of flexible expansion for:
Bivalent or bivalent-renewable operating mode
Distribution systems with unmixed and mixed heating circuits
Integrated flow sensor and soft starter, return flow sensor and external temperature sensor included in the scope of supply.
Electric cable EVL . . . to connect the heat pump and heat pump manager, must be ordered separately.
Lower operating limit heat source (heating operation) -25 °C ; Upper operating limit heat source (heating operation) 35 ° C ;
Refrigerant R290 ; Refrigerant ; Connection heating
Order reference Art.-Nr. Heat output with 1 compressor /
COP A2/W35
Connection voltage Width x Height x
Depth
mm
Weight
kg
LA 8PMS 362350
6.1 / 3.2 (3.1) 1/N/PE ~230 V, 50 Hz 1362 x 1361 x 852 232
LA 11PS 353320
9.2 / 3.1 (3.0) 3/N/PE ~400 V, 50 Hz 1550 x 1570 x 850 259
Heat output and COP according to EN 255 (EN 14511) at A2/W35 (A2 = air intake temperature +2 °C, W35 = heating water outlet temperature +35 °C) .
The high flow temperatures are available for DHW preparation all year round!
LA 8PMS 362350 4015627362352
LA 11PS 353320 4015627353329
Max. flow temperature for heating 65 °C
Casing colour white aluminium
Medium-temperature air-to-water heat pump
with two performance levels
LA 26PS
Medium-temperature air-to-water heat pump for outdoor installation with external temperature controlled WPM 2006 plus heat pump
manager and two compressors for flexible capacity. Sound-optimised through the use of noise-reducing crescent wing axial-flow fans
and air deflector hoods; energy-efficient hot gas defrosting. Universal design with optional DHW preparation and the option of flexible
expansion for:
Bivalent or bivalent-renewable operating mode
Distribution systems with unmixed and mixed heating circuits
Integrated flow sensor and soft starter, return flow sensor and external temperature sensor included in the scope of supply.
Electric cable EVL . . . to connect the heat pump and heat pump manager, must be ordered separately.
Lower operating limit heat source (heating operation) -25 °C ; Upper operating limit heat source (heating operation) 35 ° C ;
Refrigerant R290 ; Connection heating ; Connection voltage 3/N/PE ~400 V, 50 Hz
Order reference Art.-Nr. Heat output
with 1 compressor /
COP A2/W35
Heat output
with 2 compressors /
COP A2/W35
connection
voltage
Width x Height x
Depth
mm
Weight
kg
LA 14PMS 363820
5.8 / (2.9) 10.2 / (3.1) 1/N/PE ~230 V, 50 Hz 1550 x 1570 x 850 256
LA 17PS 353330
8.7 / 3.2 (3.0) 14.5 / 3.1 (3.0)
3/N/PE ~400 V, 50 Hz
1550 x 1570 x 850 330
LA 22PS 348420
10.6 / 3.0 (3.0) 16.7 / 3.1 (3.0)
1680 x 1710 x 1000
360
LA 26PS 351890
11.7 / 3.0 (3.0) 18.8 / 3.0 (3.0) 371
Heat output and COP according to EN 255 (EN 14511) at A2/W35 (A2 = air intake temperature +2 °C, W35 = heating water outlet temperature +35 °C) .
The high flow temperatures are available for DHW preparation all year round!
LA 17PS 353330 4015627353336
LA 22PS 348420 4015627348424
LA 26PS 351890 4015627351899
Heat pump for heating purposes – air source – outdoor installation
Max. flow temperature for heating 75 °C
Casing colour white aluminium
High-temperature air-to-water heat pump
with low- and high-temperature levels
LA 22HS
High temperature air-to-water heat pump for outdoor installation with external temperature controlled heat pump manager. Sound-op-
timised through the use of low-noise crescent wing axial-flow fans and deflector hoods. Energy-efficient defrosting by reverse circulation
und inclined evaporator. Universal design with optional DHW preparation and the option of flexible expansion for:
Bivalent or bivalent-renewable operating mode
Distribution systems with unmixed and mixed heating circuits
In the summer a maximum heating flow temperature of 58 °C is available for domestic hot water preparation. Integrated flow sensor and
soft starter, return flow sensor and external temperature sensor included in the scope of supply.
Electric cable EVL . . . to connect the heat pump and heat pump manager, must be ordered separately.
Lower operating limit heat source (heating operation) -25 °C ; Upper operating limit heat source (heating operation) 35 ° C ;
Refrigerant R404A ; Refrigerant R134a ; Connection heating ; Connection voltage 3/N/PE ~400 V, 50 Hz
Order reference Art.-Nr. Heat output with 1 compressor /
COP A2/W35
Heat output 2 compressor /
COP A-7/W45
Width x Height x
Depth
mm
Weight
kg
LA 22HS 340120
13.6 / 3.1 (3.0) 13.5 / 2.1
1680 x 1710 x 1000
411
LA 26HS 340130
15.9 / 3.2 (3.0) 15.2 / 2.2 418
Heat output and COP according to EN 255 (EN 14511) at A2/W35 (A2 = air intake temperature +2 °C, W35 = heating water outlet temperature +35 °C).
Heat output with 2 compressors and COP acc. to EN 14511 at A-7/W45 (A-7 = air intake temp. -7 °C, W45 = heating water outlet temp. +45 °C)
The maximum flow temperature of 75 °C is reached at an air intake temperature fr
om -25° C to +10° C (high-temperature level).
At outdoor temperatures above 10 °C, the maximum flow temperature is +58 °C (low-temperature level) .
LA 22HS 340120 4015627340121
LA 26HS 340130 4015627340138