Technical data
www.dimplex.de/en
11
2010
Air-to-water heat pump for free-standing installation
Max. flow temperature for heating 55 °C
Casing colour white aluminium
Low-temperature air-to-water heat pump
for free-standing installation
LA 16AS
Air-to-water heat pumps for outdoor installation with external temperature controlled WPM 2006 plus heat pump manager. Sound-opti-
mised through the use of low-noise crescent wing axial-flow fans and deflector hoods. Energy-efficient defrosting by reverse circulation
und inclined evaporator. Universal design with optional DHW preparation and the option of flexible expansion for:
• Bivalent or bivalent-renewable operating mode
• Distribution systems with unmixed and mixed heating circuits
Integrated flow sensor and soft starter, return flow sensor and external temperature sensor included in the scope of supply.
Electric cable EVL . . . to connect the heat pump and heat pump manager, must be ordered separately.
Lower operating limit heat source (heating operation) -25 °C ; Upper operating limit heat source (heating operation) 35 ° C ;
Refrigerant R404A ; Connection heating 1 ⬙
Order reference Art.-Nr. Heat output with 1 compressor /
COP A2/W35
Connection voltage Width x Height x
Depth
mm
Weight
kg
LA 11MS 342420
9.1 / 3.4 (3.3)
1/N/PE ~230 V, 50 Hz
1360 x 1360 x 850 219
LA 16MS 351270
12.7 / 3.2 (3.0) 1550 x 1570 x 850 264
LA 11AS 339950
8.8 / 3.2 (3.1)
3/N/PE ~400 V, 50 Hz
1360 x 1360 x 850 219
LA 16AS 339960
12.2 / 3.2 (3.1) 1550 x 1570 x 850 264
Heat output and COP according to EN 255 (EN 14511) at A2/W35 (A2 = air intake temperature +2 °C, W35 = heating water outlet temperature +35 °C) .
LA 11MS 342420 4015627342422
LA 16MS 351270 4015627351271
LA 11AS 339950 4015627339958
LA 16AS 339960 4015627339965
Max. flow temperature for heating 55 °C
Flow temperature cooling min. 7 °C
Casing colour white aluminium
Reversible air-to-water heat pump
Optimised for heating
LA 11MSR
Air-to-water heat pump for outdoor installation with external temperature controlled heat pump manager WPM 2006 R and reversible
refrigerating circuit for heating and cooling. Sound-optimised through the use of low-noise crescent wing axial-flow fans and deflector
hoods. Energy-efficient defrosting by reverse circulation und inclined evaporator. Universal design with optional DHW preparation and
the option of flexible expansion for:
• bivalent operation (bivalent-renewable not possible)
• combined distribution systems for heating and cooling
• unmixed and mixed heating and cooling circuits
Silent cooling via panel heating/cooling systems requires the use of the room climate control station (special accessory) to regulate the
flow temperature on the basis of the air temperature and humidity of a reference room.
Electric cable EVL . . R to connect the heat pump and heat pump manager must be ordered separately.
Lower operating limit heat source (heating operation) -25 °C ; Upper operating limit heat source (heating operation) 35 °C ;
Lower operating limit heat source (cooling operation) 15 °C ; Upper operating limit heat source (cooling operation) 40 °C ;
Refrigerant R404A ; Connection heating 1 ⬙ ; Connection voltage 1/N/PE ~230 V, 50 Hz
Order reference Art.-Nr. Heat output with
1 compressor /
COP A2/W35
Cooling capacity
1 compressor /
EER A27/W7
Width x Height x
Depth
mm
Weight
kg
LA 11MSR 342690
8.9 / 3.4 (3.3) 8.8 / 2.8 1360 x 1360 x 850 224
Heat output and COP according to EN 255 (EN 14511) at A2/W35 (A2 = air intake temperature +2 °C, W35 = heating water outlet temperature +35 °C).
Cooling capacity and coefficient of performance according to EN 14511.
LA 11MSR 342690 4015627342699
Heat pump for heating purposes – air source – outdoor installation