Technical data

Device Information for Brine-to-Water Heat Pumps with Simplified Regulation 5.2
www.dimplex.de 21
5.2 Reversible brine-to-water heat pumps for indoor installation, three-
phase
Device information for brine-to-water heat pumps for heating purposes
1 Type and order code
SI 12TR SI 14TR SI 16TR SI 20TR
2Design
2.1 Design Reversible Reversible Reversible Reversible
2.2 Degree of protection according to EN 60 529 IP20 IP20 IP20 IP20
2.3 Installation location Indoors Indoors Indoors Indoors
3 Performance data
3.1 Operating temperature limits:
Heating water flow °C Up to 60 Up to 60 Up to 60 Up to 60
Cooling, flow °C +7 to +20 +7 to +20 +7 to +20 +7 to +20
Brine (heat source, heating) °C -5 to +25 -5 to +25 -5 to +25 -5 to +25
Brine (heat sink, cooling) °C +5 to +25 +5 to +25 +5 to +25 +5 to +25
Antifreeze
Monoethylene
glycol
Monoethylene
glycol
Monoethylene
glycol
Monoethylene
glycol
Minimum brine concentration (-13 °C freezing temperature) 25% 25% 25% 25%
3.2 Temperature spread of heating water (flow/return flow) at B0 / W35K 9.9 9.4 9.6 10.7
3.3 Heat output / COP at B-5 / W55
1
kW / ---
1. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, both the bivalence point and the regulation should
also be taken into consideration. The specified values, e.g. B10 / W55, have the following meaning: Heat source temperature 10 °C and heating water flow temperature 55 °C.
9,8 / 2,1 12,2 / 2,3 14,1 / 2,4 18,7 /2,5
at B0 / W50
1
kW / ---
11,3 / 2,9 13,5 / 2,9 16,3 / 3,2 20,4 / 3,1
at B0 / W35
1
kW / ---
11,6 / 4,1 13,7 / 4,0 16,4 / 4,0 20,0 / 4,2
3.4 Cooling capacity / COP at B20 / W8 kW / --- 11,4 / 4,6 14,1 / 5,0 17,3 / 4,9 21,5 / 4,9
at B20 / W18 kW / --- 14,1 / 5,3 17,4 / 5,9 21,5 / 5,9 26,0 / 5,7
at B10 / W8 kW / --- 11,6 / 5,7 14,7 / 6,4 18,0 / 6,4 21,9 / 5,9
at B10 / W18 kW / --- 14,1 / 6,5 17,4 / 7,1 21,5 / 7,3 27,7 / 7,1
3.5 Sound power level dB(A) 56 56 56 56
3.6 Heating water flow with an internal pressure
differential of m³/h / Pa
1,0 / 4100 1,3 / 4850 1,5 / 4000 1,6 / 3400
3.7 Brine flow with an internal pressure differential
(heat source) of m³/h / Pa
3,0 / 24000 3,5 / 17900 3,8 / 18400 3,5 / 13900
3.8 Refrigerant; total filling weight type / kg R407C / 1.4 R407C / 2.1 R407C / 2.4 R407C / 3.2
4 Dimensions, connections and weight
4.1 Device dimensions without connections
2
H x W x L mm
2. Note that additional space is required for pipe connections, operation and maintenance.
1220 x 640 x 624 1220 x 640 x 624 1220 x 640 x 624 1220 x 640 x 624
4.2 Device connections to heating system Inch G 1'' external G 1'' external G 1'' external G 1'' external
4.3 Device connections to heat source Inch G 1'' external G 1'' external G 1¼" external G 1¼" external
4.4 Weight of the transportable unit(s) incl. Packing kg 164 166 172 237
5 Electrical Connection
5.1 Nominal voltage; fuse protection V / A 400 / 16 400 / 16 400 / 16 400 / 16
5.2 Nominal power consumption
1
B0 W35 kW
2.8 3.41 4.1 4.8
5.3 Starting current with soft starter A 26 26 30 30
5.4 Nominal current B0 W35 / cos ϕ A / --- 4,8 / 0,8 6,2 / 0,8 7,4 / 0,8 11,0 / 0,8
6 Complies with the European safety regulations
3333
7 Additional model features
7.1 Water in device protected against freezing
3
3. The heat circulating pump and the heat pump controller must always be ready for operation.
No No No No
7.2 Performance levels 1 1 1 1
7.3 Regulator internal/external Internal Internal Internal Internal