User Manual

ELECTRICAL CONNECTION
WARNING: THIS APPLIANCE MUST BE EARTHED
This heater must be used on an A.C.~ supply only and
the voltage marked on the heater must correspond
to the supply voltage. These heaters are fitted with a
plug incorporating a 10 amp fuse for 2kW heaters or
a 13 amp fuse for 3kW heaters. When replacing the
fuse, a 10 or a 13 amp fuse approved by ASTA to BS
1362 must be used.
If the plug is damaged or not suitable for the socket
DO NOT operate the radiator with the mains lead
overhanging the outlet grille.
If the radiator is tipped over, unplug it and allow it to
cool before standing it back up.
DO NOT pull, carry or move the appliance using the
power cable.
The supply cord should be uncoiled before use.
This instruction leaflet belongs to the appliance and
must be kept in a safe place. If changing owners, the
leaflet must be surrendered to the new owner.
outlets in your home, the plug must be cut off and an
appropriate one fitted. A plug cut off from a mains
lead will give a shock hazard if inserted into a 13 amp
socket elsewhere in the house. To avoid this, it should
be disposed of immediately.
NOTE: The fuse cover of a non-rewirable plug must
be refitted when changing the fuse. Should the cover
become lost, the plug must be replaced.
IMPORTANT: The wires in this mains lead are coloured
in accordance with the following code:
BLUE: NEUTRAL
BROWN: LIVE
GREEN & YELLOW: EARTH
As the colours of the wires in the mains lead may not
correspond with the coloured markings in your plug,
proceed as follows:
Connect the BROWN wire to the terminal marked
‘L’ or coloured RED. Connect the BLUE wire to the
terminal marked ‘N’ or coloured BLACK. Note: ‘L’ or
‘N’ must not be connected to the EARTH terminal
marked ‘E’ or ‘
’ or coloured GREEN or GREEN AND
YELLOW. If in doubt, consult your electrician.
590 (FutM2BT)
740 (FutM3BT)
306
630
Models
Model Description Power
FutM2CE
Electronic thermostat control with 12 hour Runback or Delayed start timer
2.0 kW
FutM3CE
Electronic thermostat control with 12 hour Runback or Delayed start timer
3.0 kW
General
The radiator is designed for operation on an AC electricity supply, and is suitable for use in domestic dwellings
and similar indoor locations.
The radiator is fitted with castors and handles for ease of movement. An electronic thermostatic control provides
precise room temperature control with Runback timer and Delayed start functionality. It is supplied with a cord
and plug and is ready for use once the castors have been correctly fitted.
Dimensions & Range Info