Use and Care Manual

7
Site Selection
Review and consider all of the
following conditions for installation:
Dimensions of the unit: 50
5
/
16
"
(128 cm) x 19½"(49.5 cm)
Unit requires a minimum of two wall
studs in order to ensure a secure
installation
There are three possible mounting
methods:
Surface mount (pg. 12);
Partial recess (pg. 13);
Flush mount (pg. 14),
and any of these have the option of
being hardwired or plugged directly
into the wall outlet.
WARNING: The top of the
replace is to be installed at least
4" (10.2 cm) from the ceiling.
CAUTION: Ensure installation
does not allow replace to be in
direct contact with building vapor
barrier or insulation and meets all
local building codes.
!
NOTE 1: A 15 Amp, 120 Volt
circuit is required. A dedicated
circuit is preferred but not essential
in all cases. A dedicated circuit will
be required if, after installation, the
circuit breaker trips or fuse blows
on a regular basis when the heater
is operating. Additional appliances
on the same circuit may exceed
Fireplace Installation
the current rating of the circuit
breaker.
WARNING: Ensure the power
cord is not installed so that it is
pinched or against a sharp edge
and ensure that the power cord
is stored or secured to avoid
tripping or snagging to reduce
the risk of re, electric shock or
injury to persons. Construction and
electrical outlet wiring must comply
with local building codes and other
applicable regulations to reduce
the risk of re, electric shock and
injury to persons.
WARNING: To reduce the risk of
re, do not store or use gasoline,
or other ammable vapors or
liquids in the vicinity of the heater.