Service Manual Model Number DS5629 UL Part Number 6900471359 IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to service this stove. For your safety, always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property damage. REV Dimplex North America Limited 1367 Industrial Road Cambridge ON Canada N1R 7G8 1-888-346-7539 www.dimplex.
TABLE OF CONTENTS OPERATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 EXPLODED PARTS DIAGRAM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPERATION Figure 1 Remote Control The stove is supplied with a radio frequency remote control. This remote control has a range of approximately 50 feet (15.25 m), it does not have to be pointed at the stove and can pass through most obstacles (including walls). It is supplied with one of hundreds of independent frequencies to prevent interference with other units.
MAINTENANCE WARNING: Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire, electric shock or damage to persons. Light Bulb Replacement Allow at least 5 minutes for light bulbs to cool off before touching bulbs to avoid accidental burning of skin. Light bulbs need to be replaced when you notice a dark section of the flame or when the clarity and detail of the log exterior disappears. There are two bulbs under the log set which generate the flames and embers.
EXPLODED PARTS DIAGRAM 10 15 5 20 17 6 11 4 16 7 9 8 13 22 20 2 1 18 12 19 3 14 1. Cutout . . . . . . . . . . . . . . . . . . . . . . . . . . 2300270100RP 2. Flicker Motor DS5629GB/CR MOD 0 - A. . . . . . . . . . . 2000210200RP DS5629GP/BR MOD 0 . . . . . . . . . . . . . 2000210200RP DS5629GB/CR MOD B. . . . . . . . . . . . . 2000500100RP DS5629GP/BR MOD A . . . . . . . . . . . . . 2000500100RP *If unit does not have a terminal block send WIRE-CON-KIT 3. Heater/Blower Assembly. . . . . . . .
WIRING DIAGRAM DS5629GB/CR MOD 0 - A and DS5629GP/BR MOD 0 DS5629GB/CR MOD B and DS5629GP/BR MOD A 6 www.dimplex.
LIGHT BULB REPLACEMENT CAUTION: If unit was operating prior to servicing allow at least 5 minutes for lights to cool off to avoid accidental burning of skin. Figure 4 WARNING: Disconnect power before attempting any maintenance to reduce the risk of electric shock or damage to persons. Light bulbs need to be replaced when you notice a dark section of the flame or when the clarity and detail of the log exterior disappears. There are three bulbs under the log set which generate the flames and embers.
front of the emberbed and remove the grate from the unit. 3. Remove the logset from the unit by pulling forward and lifting out. 4. Remove the reflector rod from the flame motor by pulling the end of the rod to the left and carefully remove flame rod from rubber sleeve. 5. Reassemble in the reverse order as above.
Figure 8 10. Remove the thermostat knob and 2 mounting screws. 11. Connect all of the wiring connections in their original locations. 12. Reassemble in the reverse order as above. POWER CORD REPLACEMENT WARNING: If the stove was operating prior to servicing, allow at least 10 minutes for light bulbs and heating elements to cool off to avoid accidental burning of skin. ! NOTE: New mounting studs are supplied with the replacement remote control receiver. 8. Reassemble in the reverse order as above.
6. Pull the power cord out through the hole in the rear cover. 7. Install the new power cord through the hole in the rear cover by placing the strain relief over the cord, hold the strain relief with pliers and slide into mounting hole. 8. Connect all of the wiring connections in their original locations. 9. Reassemble in the reverse order as above.
TROUBLESHOOTING GUIDE PROBLEM CAUSE SOLUTION General Circuit breaker trips or fuse blows when unit is turned on Short in unit wiring. Trace wiring in unit. Improper circuit current rating Additional appliances may exceed the current rating of the circuit breaker or fuse. Plug unit into another outlet or install unit on a dedicated 15 amp circuit. Unit turns on or off by itself Remote control has a similar frequency to other remotes in the area.
PROBLEM CAUSE SOLUTION Heater Heater is not turning off Improper operation Refer to Operation Section Defective heater on/off switch Replace heater on/off switch Defective Thermostat Replace Thermostat Defective Remote Control Receiver Replace Remote Control Receiver, initialize with remote control Improper operation Refer to Operation Section Loose wiring Check wiring connections Defective heater on/off switch Replace heater on/off switch Defective Thermostat Replace Thermostat Defectiv