Use And Care Manual
11
Site Selection
600mm
(23.6")
Min.
600mm
(23.6")
Min.
600mm (23.6") Min.
165mm
(6.5")
Min.
910mm (35.4") Min. to surfaces (ie. table tops, etc.)
2100mm (82.7") Min. from oor
3000mm (118.1") Max. from oor (recommended)
Fans, lights and
sprinkler fittings
MUST NOT
be below heater
IR heater, same minimum
clearance requirements
for both ends of heater
installation
WALL
CEILING
WALL
CEILING
Fans, lights and
sprinkler fittings
MUST NOT
be below heater
600mm
(23.6")
Min.
150mm
(5.9")
Min.
1500mm
(59.1")
Min.
600mm (23.6") Min.
910mm (35.4") Min. to surfaces (ie. table tops, etc.)
2100mm (82.7") Min. from oor
3000mm (118.1") Max. from oor (recommended)
WALL
CEILING
WALL
CEILING
IR heater, same minimum
clearance requirements
for both ends of heater
installation
WALL
CEILING
Correct Installation
Fans, lights and
sprinkler fittings
MUST NOT
be below heater
240mm (9.4")
Min.
1500mm (59.1")
Min.
105mm
(4.1") Min.
600mm (23.6") Min.
910mm (35.4") Min. to surfaces (ie. table tops, etc.)
Canada 2400mm (94.5") Min. from oor
US 1800mm (70.9") Min. from oor
WALL
CEILING
WALL
CEILING
IR heater, same minimum
clearance requirements
for both ends of heater
installation
Minimum clearances when mounting the heater parallel with a ceiling.
Minimum clearances when mounting the heater at an angle to the ceiling.
Wall-mounted
installation
(DIR15A10GR,
DIR18A10GR,
DIR22A10GR,
DIR30A10GR)
Minimum clearances when mounting the heater on A VERTICAL WALL.