Site Selection
!
NOTE: A 15 Amp, 120
Volt circuit is required. A
dedicated circuit is preferred
but not essential in all cases.
A dedicated circuit will be
required if, after installation,
the circuit breaker trips or the
fuse blows on a regular basis
when the heater is operating.
Additional appliances on the
same circuit may exceed the
current rating of the circuit
breaker.
WARNING: Ensure the power
cord is not installed so that
it is pinched or against a
sharp edge and ensure that
the power cord is stored or
secured to avoid tripping or
snagging to reduce the risk of
re, electric shock or injury to
persons.
Construction and electrical
outlet wiring must comply
with local building codes and
other applicable regulations to
reduce the risk of re, electric
shock and injury to persons.
Do not attempt to wire your
own new outlets or circuits. To
reduce the risk of re, electric
shock or injury to persons,
Fireplace Installation
always use a licensed
electrician.
WARNING: The supplied
mounting bracket is designed
for use with Dimplex wall
mounted replaces only.
Improper use, or use for
purposes other than intended,
may cause damage or injury.
Installation
WARNING: Failure to install
the replace as instructed
below may result in damage
to the equipment and or may
expose the user to the risk of
re, serious injury, illness or
death.
WARNING: The replace
requires the wall mounting
bracket screws to be installed
into a minimum of two wall
studs (Figure 2).
Tools Required
#2 Phillips screwdriver
Pencil
Slot screwdriver
Bubble level (supplied)
Drill, and drill bits as required
Approximate time: 30 minutes
for installation
1. Select an appropriate location
to mount the unit on a wall,
above an electrical outlet.