PARTS & SERVICE MANUAL FOR THE 32” MULTIFIRE™ FIREPLACE MODEL NUMBER: DF3215
TABLE OF CONTENTS OPERATION PAGE 1 PARTS DRAWING PAGE 5 PARTS LIST PAGE 6 WIRING DIAGRAM PAGE 7 LIGHT BULB REPLACEMENT PAGE 8 FILTER REPLACEMENT PAGE 10 REMOTE CONTROL SWITCH BOARD REPLACEMENT PAGE 11 REMOTE CONTROL RECEIVER REPLACEMENT PAGE 12 FLAME MOTOR/FLAME ROD REPLACEMENT PAGE 13 MAIN ON/OFF SWITCH REPLACEMENT PAGE 15 HEATER ASSEMBLY REPLACEMENT PAGE 16 POWER CORD REPLACEMENT PAGE 17
DF3215 OPERATION ELECTRIC FIREPLACE MANUAL CONTROL The manual controls for the fireplace are located in the upper right hand corner. A. Main On/Off Switch Supplies power to the 3 position manual control switch. B. 3 Position Manual Control Switch Position 1 (left position): The unit is operated with the remote control. Position 2 (center position): The flame effect is turned ON. Position 3 (right position): The flame effect and heater are turned ON simultaneously.
DF3215 REMOTE CONTROL The remote control has a range of approximately 50 ft. (15.25m), it does not have to be pointed at the fireplace and can pass through most obstacles (including walls). It is supplied with 243 independent frequencies to prevent interference with other units. BATTERY INSTALLATION 1. Depress tab on the battery cover on the back of the remote transmitter and remove battery cover. 2. Install 3 AAA batteries into the remote control (included). 3. Replace the battery cover.
DF3215 FREQUENCY INTERFERENCE If the fireplace does not respond properly to the remote control, the remote operating frequency may have to be reset. The remote control can send another frequency code to the circuit board to eliminate interference. 1. Press the ENTER button on the remote control, the middle display flashes. 2. Use the direction buttons on the hand held remote to move the cursor to and press ENTER. 3. Press and hold the initialization button on the unit. 4.
DF3215 REMOTE CONTROL FUNCTIONS Room temperature Set temperature Time of day Low Battery Indicator Day of week Remote display Up direction button Enter button Left direction button Flame/Heat ON/OFF button Right direction button Down direction button Purifire™ ON/OFF button Occupancy Sensor Batteries Sleep timer Ambient Light Sensor FIGURE 5 FLAME/HEAT ON/OFF BUTTON Press the Flame/Heat On/Off button to turn the Flame/Heat function ON.
DF3215 3 15 2 18 7 12 10 7 3 11 1 6 14 5 13
DF3215 REPLACEMENT PARTS FIREBOX, 32" - DIMPLEX - MULTIFIRE – CATALOGUE NO. PART NO. MOD LEVEL: MADE IN: DF3215 6902520159 NONE CHINA REPLACEMENT PART 1. 30” URETHANE LOG SET ASSEMBLY 2. HEATER ASSEMBLY 3. UPPER & LOWER LIGHT ASSEMBLY 4. WIRE HARNESS – RECEIVER TO BLOWER 5. WIRE HARNESS – RECEIVER TO LOGSET 6. FLAME MOTOR 7. REMOTE CONTROL – SENDER 8. REMOTE CONTROL RECEIVER 9. REMOTE CONTROL SWITCH BOARD 10. CORD SET 11. REFLECTOR ROD 12. MIRROR, SEMI-SILVERED 13. FOOT 14. STEEL CURTAIN 15.
DF3215 WIRING DIAGRAM 7
DF3215 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. Light bulbs need to be replaced when you notice a dark section of the flame. There are four bulbs under the log set which generate the flames and embers.
DF3215 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. Light bulbs need to be replaced when you notice a dark section of the flame. There are four bulbs under the log set which generate the flames and embers.
DF3215 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. FILTER REPLACEMENT 1. Open the bi-fold doors. 2. Remove the 3 mounting screws from the air filter bracket. 3. Remove the air filter bracket assembly from the firebox. 4. Slide filter out of air filter bracket. 5.
DF3215 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE REMOTE CONTROL SWITCH BOARD 1. Remove firebox from mantel. 2. Remove (8) screws from top panel. 3. Disconnect the 10” wire harness from the remote control switch board. 4.
DF3215 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE REMOTE CONTROL RECEIVER 1. Remove firebox from mantel. 2. Remove (8) screws from top panel. 3. Remove wiring connections from remote control receiver noting their original locations. 4.
DF3215 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE FLAME MOTOR/FLAME ROD 1. Open the bi-fold doors. 2. Pull the front edge of the plastic ember bed or plastic grate up and forward until the rear tab releases from the ledge located at the bottom of the mirror.
DF3215 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE FLAME MOTOR/FLAME ROD 15. Repeat this process for the (4) remaining wires. (red, blue, orange, grey) 16. Reconnect the logset LED wire harness. 17.
DF3215 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE MAIN ON/OFF SWITCH 1. Remove firebox from mantel. 2. Remove (8) screws from top panel. 3. Remove wiring connections from main on/off switch noting their original locations. 4.
DF3215 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE HEATER ASSEMBLY 1. Remove firebox from mantel. 2. Remove (8) screws from top panel. 3. Remove wiring connections from heater assembly noting their original locations. 4.
DF3215 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE POWER CORD 1. Remove firebox from mantel. 2. Remove (8) screws from top panel. 3.