Service manual
4 www.dimplex.com
MAINTENANCE
WARNING: Disconnect power before attempting any
maintenance or cleaning to reduce the risk of re,
electric shock or damage to persons.
Light Bulb Replacement
CAUTION: Allow at least 10 minutes for light bulbs and
heater assmebly to cool off before touching bulbs to avoid
accidental burning of skin.
Light bulbs need to be replaced when you notice a dark
section of the ame. There are two (2) bulbs under the log
set which generate the ames and embers.
Approximate time: 15 minutes to change the light bulbs.
Light Bulb Requirements
Quantity of two (2) clear chandelier or candelabra bulbs with
an E-12 (small) socket base, 60 Watt rating. Example: GE
60BC or Philips 60CTC.
Required tools: Phillips screw driver.
1. Remove the front glass by removing the two (2) outer
screws holding the glass clips (Figure 3).
2. Remove the log grate by removing the two (2)
mounting screws (Figure 4).
3. Remove the log set by lifting straight up (Figure 5).
4. Slide the light assembly slightly out of the insert
approximately one (1) inch.
5. Examine the bulb(s) to determine which bulb(s) require
replacement.
6. Unscrew the bulbs counter clockwise.
7. Insert new bulbs.
8. Slide the light assembly back into the insert.
9. Replace the log set into the insert.
10. Reinstall the log grate.
11. Reinstall the front glass.
Glass Cleaning
The glass is cleaned in the factory during the assembly
operation. During shipment, installation, handling, etc., the
clear door may collect dust particles, these can be removed
by dusting lightly with a clean dry cloth.
To remove ngerprints or other marks, the clear door can
be cleaned with a damp cloth. The clear door should be
completely dried with a lint free cloth to prevent water
spots. To prevent scratching, do not use abrasive cleaners
or spray liquids on the clear door surface.
Fireplace Surface Cleaning
Use warm water only to clean painted surfaces. Do not use
abrasive cleaners on glass surface or spray liquids directly
onto any surface.
Unit Storage
Store the unit when not in use in a dry, dust free location
with the power cord properly secured.
Figure 4
Figure 5
Log set
Light
Assembly
Light bulbs
Log grate
Front
Glass
Glass
Clips
Figure 3
Glass clip
and outer screw