Owner`s manual
  13
 Maintenance
Light Bulb Replacement
Light bulbs need to be replaced 
when you notice a dark section 
of the ame. There are two (2) 
bulbs under the log set which 
generate the ames and embers.
Light Bulb Requirements
Quantity of two clear chandelier 
or candelabra bulbs with an E-12 
(small) socket base, 60 Watt rat-
ing. Example: GE 60BC or Philips 
60CTC. Do not exceed 60 Watts 
per bulb.
Replacement:
 CAUTION: Allow at least 10 
minutes for light bulbs and heater 
to cool off before touching bulbs 
to avoid accidental burning of 
skin.
1.  Remove the front glass by 
removing the 2 outer screws 
holding the glass clips (Figure 
5).
2.  Remove the log grate by 
removing the 2 mounting 
screws (Figure 6).
3.  Remove the log set by lifting 
Figure 6
Figure 7
Log set
Light 
assembly
Light bulbs
Log grate
Front
glass
Glass
clips