Dimplex Air Conditioner – DAC 9000
CONTENTS. Page Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Important Safeguards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The ventilation mode "moves" the air allowing for its recycling. The cooling mode, a refrigerating circuit (compressor), cools the room by transferring the heat from inside to outside though the air exhaust hose.While cooling, the airconditioning unit also dehumidifies the room air. Humidity absorbed from the air condenses and turns into water that is collected in the internal tank.
Important Safeguards. • The air conditioning unit must always be stored and transported upright. Otherwise you may cause irreparable damage to the compressor; in case of doubt we suggest you wait for at least 24 hours before you start the air-conditioner. • Avoid restarting the air conditioning unit unless 4 minutes have passed since it was turned off or the compressor may suffer damage. • Never use the mains plug as a switch to start and turn off the air conditioning unit.
• Please read the instructions carefully and save them in a safe place for future reference. 5 6 1 7 2 8 3 9 4 Know your Air Conditioner. 1. Control panel 6. Air inlet 2. Cooling air outlet 7. Exhaust air outlet 3. Handle 8. Cord storage 4. Castors 9. Water stopper (rubber plug inside) 5.
Accessories. 6 1. Adaptor - for insertion over hose and into back of the air conditioner. 1 2. Adaptor - for insertion over hose and into foam strip. 2 3 3. Exhaust hose. 4. Foam strip - for filling the open window space and with hole for connection to exhaust hose. 7 5. Foam strip - for filling the open window space. 4 6. Round window connector. 8 7. Cap for round window connector. 8. Water tray. 5 Installation. Mounting of the unit This unit is a PORTABLE AIR CONDITIONER.
Round window connector 2. Using the round window connectors. • Make a hole (diameter 112mm) in the wall/glass to fit the supplied round window connector. • Take off the adaptor (the one which does not connect with the unit), fit the hose directly to the round window connector. cm 50 • When the hole is not in use. Use the cap for the round window connector to cover the hole. Mounting of the exhaust pipe 1. The supplied exhaust hose can be extended from 300 to 1500mm for mounting.
Operation. 1 1. Power indicator 2 3 4 DAC - 9000 2. Fan operating indicator UR TIMER HO 1 ERMOSTAT TH 3. Cooling operating indicator SPEED 2 3 8 4. FULL WATER indicator 4 7 6 5. Timer (1-8 hours) as well as ON/OFF switch 7 5 5 6. Speed switch with options for - LOW FAN, HIGH FAN, LOW COOL, HIGH COOL. 6 7. Thermostat SPEED Turning ON/OFF • Set TIMER to ON for continuous operation (the unit will operate as long as it is not turned off). Power indicator comes on.
Drainage. During the process of cooling, water will be generated from the air and collected in the water tank inside the unit.When the tank is full, the compressor will stop and the Full Water indicator on the control panel will come on to remind you to empty the water tank. During this time the fan will continue to operate, circulating the air.The water tank should be emptied as follows: 1. Turn off the unit. 2. Position the supplied plastic water tray, flat on the floor, under the drain hole. 3.
Dehumidification. NOTE! The machine operates in the cooling mode but it does not lower the room temperature. It absorbs the excessive humidity present in the air. 1. Plug the unit into proper electrical outlet. 2. Position the exhaust tube as shown or remove from the air-conditioner. 3. Turn the TIMER to position ON or 1 to 8 hours automatic timer setting. 4. Set the FAN SPEED control to the desired output of airflow, high or low. 5. Set the THERMOSTAT to the maximum cooing position. 6.
NOTICE! Never operate the unit without the filters. End of season storage • Unplug the unit. • Drain the condensed water COMPLETELY (Please refer to drainage clause). • Clean or change the filter. • Turn on the unit in ventilation mode for a couple of hours, so the inside can dry out completely. • It is recommended that the unit be put back into the original carton for storage and do not stack heavy objects on top of the unit.