14
TROUBLESHOOTING GUIDE
GENERAL
Problem Cause Solution
Service Manual
Reference
Circuit breaker trips
or fuse blows when
unit is turned on
Improper circuit current rating
Additional appliances may
exceed the current rating of
the circuit breaker or fuse.
Plug unit into another outlet
or install unit on a dedicated
15 amp circuit
Lights dim in room
while the unit is on
Unit is drawing close to circuit
current rating
Move the unit to another
outlet or install unit on a
dedicated 15 amp circuit
Power cord gets
warm
Normal operation
The power cord may get
slightly warm to the touch
when the heater is on
Defective power cord
Replace power cord
Page 12
APPEARANCE
Problem Cause Solution
Service Manual
Reference
Fireplace does not
turn on
Improper operation Refer to Operation Section Page 2
Defective main on/off switch Replace main on/off switch Page 8
Loose wiring Check wiring connections Page 5
Flame frozen
Defective flame motor Replace flame motor Page 11
Loose wiring Check wiring connections Page 5
Flame not bright or
flame not visible
Burnt light bulbs Replace light bulbs Page 6
Loose wiring Check wiring connections Page 5
Defective light harness Replace light harness Page 7
Log set dim, ember
bed not glowing
Burnt light bulbs Replace light bulbs Page 6
Flame Shutter Defective flame motor Replace flame motor Page 11