Site Selection
Review and consider all of the
following conditions before instal-
lation:
• Dimensions of the unit: 74.1 in.
(1883 mm) x 19.4 in. (494 mm)
• For surface installation, the unit
requires a minimum of 2 wall
studs in order to ensure secure
installation. For other installa-
tion methods, suitable framing
is required.
There are two possible mounting
methods:
• Surface mount (pg. 10);
• Flush mount (pg. 11).
!
NOTE: If the desired replace
location is on the interior of an ex-
terior wall the unit should only be
surface mounted. If an in-wall or
ush mount look is desired build
the interior wall out into the room.
!
NOTE: A dedicated, properly
fused 15 Amp circuit is re-
quired, rated for the appropri-
ate voltage (120V, 240V).
WARNING: Construction and
electrical outlet wiring must
comply with local building
codes and other applicable
regulations to reduce the risk
of re, electric shock and injury
Fireplace Installation
to persons.
WARNING: To reduce the risk
of re, do not store or use gaso-
line or other ammable vapors or
liquids in the vicinity of the heater.
1. Select a location that is not
susceptible to moisture and
is away from drapes, furniture
and high trafc.
2. Unpack the replace, front
glass and hardware from the
box and remove all packaging
Figure 2
Screws
Electrical Cover Bracket
Figure 3