Owner's Manual

7
Site Selection
Review and consider all of the fol-
lowing conditions for installation:
Dimensions of the unit: 50
5
/
16
"
(128cm) x 19½"(49.5cm)
Unit requires a minimum of two
wall studs in order to ensure a
secure installation
There are three possible mount-
ing methods:
Surface mount (pg. 11);
In-wall Recessed (pg. 13);
Flush mount (pg. 14),
and any of these have the option
of being hard-wired or plugged
directly into the wall outlet.
CAUTION: Ensure installation
does not allow replace to be in
direct contact with building vapor
barrier or insulation and meets all
local building code.
!
NOTE 1: A 15 Amp, 120 Volt
circuit is required. A dedicated
circuit is preferred but not essen-
tial in all cases. A dedicated circuit
will be required if, after installa-
tion, the circuit breaker trips or
fuse blows on a regular basis
when the heater is operating. Ad-
ditional appliances on the same
circuit may exceed the current
rating of the circuit breaker.
Fireplace Installation
WARNING: Ensure the power
cord is not installed so that it
is pinched or against a sharp
edge and ensure that the
power cord is stored or secured
to avoid tripping or snagging to
reduce the risk of re, electric
shock or injury to persons.
Construction and electrical
outlet wiring must comply
with local building codes and
other applicable regulations to
reduce the risk of re, electric
shock and injury to persons.
WARNING: To reduce the risk
of re, do not store or use gaso-
line, or other ammable vapors or
liquids in the vicinity of the heater.
Grounding Instructions
This product must be grounded.
If it should malfunction or break-
down, grounding provides a path
of least resistance for electric
current to reduce the risk of
electric shock. This product is
equipped with a cord having an
equipment-grounding conductor
and a grounding plug. The plug
must be plugged into an appropri-
ate outlet that is properly installed
and grounded in accordance with
all local codes and ordinances.
DANGER: Improper connec-