Fireplace Installation
6. Remove fireplace from wall
and store in a safe place away
from traffic.
7. Where marked screw locations
do not line up with a wall stud,
insert (screw in) one of the two
supplied wall anchors (predrill
if required). Repeat if only two
screws line up with a wall stud.
8. Screw all four supplied #8,
1½ in. (3.8 cm) square head
mounting screws and wash-
ers into the wall and/or wall
anchors leaving ¼ in. (6.5 mm)
of thread.
9. Align chosen key-holes with
screws and hang replace on
the wall. Screw heads and
washers will t through key-
holes and replace will slide
down into place (screws will
slide into narrow part of key-
holes).
10. Tighten all four mounting
screws down on replace
chassis.
11. Screw the two supplied #8
square head screws through
two of the permanent mount-
ing holes which align with a
wall stud.
12. Carefully replace and install
partially reflective glass and
glass brackets using screws
from step 1.
13. Refer to Front Glass Installa-
tion section for nal installation
procedures.
In-wall Recessed Installation
- 2x4 Framing
CAUTION: Two people may
be required for various steps
of this procedure.
1. Prepare a wall with a framed
opening of 46 ½ in. (118.1 cm)
wide x 16 ½ in. (42 cm) high
(Figure 10).
!
NOTE: The sizing has allowed
for 1/4 in. (6.4 mm) around the
replace insert for ease of instal-
Figure 10
2 x 4 Framing