Owner's Manual
12 www.dimplex.com
Fireplace Installation
an outlet on a nearby wall stud
within the wall).
• Hard wire the replace (recom-
mended). Follow the hard wiring
instructions on page 8.
WARNING: Do not attempt to wire
your own new outlets or circuits. To
reduce the risk of re, electric shock or
injury to persons, always use a licensed
electrician.
WARNING: Ensure that the
circuit on which the replace is to
be installed has the power cut off at
the service panel until installation is
complete.
3. Lift replace and insert into open-
ing (Figure 8).
4. Use the supplied bubble level to
level the replace within the fram-
ing, adjust as required.
5. Drive four supplied mounting
screws through the four mounting
holes located in each corner of the
replace chassis, into wall studs
(Figure 8).
6. Refer to Front Glass Installa-
tion section for nal installation
procedures.
Flush Mounted
Installation - 2x8 Framing
CAUTION: Two people may be
required for various steps of this
procedure.
1. Prepare a wall with a framed
opening of 33 in. (83.8 cm) wide x
18 ½ in. (47 cm) high (Figure 9).
!
NOTE: The sizing has allowed for
¼ in. (6.4 mm) around the replace
insert for ease of installation. This
replace does not require any ad-
ditional venting.
!
NOTE: It is recommended that
the bottom of the unit not be mounted
higher than 40 in. (102 cm) from the
ground to maintain an optimized view-
ing angle of the ame.
2. Choose your method of supplying
power to the unit:
• Plug in (you may run the power
cord out of the framed wall open-
ing to an existing outlet or install
an outlet on a nearby wall stud
within the wall).
• Hard wire the replace (recom-
mended). Follow the hard wiring
Figure 8
Mounting hole
Mounting
holes