4 www.dimplex.com
Voltage Selector Switch
The BFSL33 has 2 voltage options at the time of installa-
tion, 110/120v and 220/240v. The voltage selector switch is
to be set at the time of installation according to the voltage
coming from the power supply.
The switch is located on the top right hand side of the re-
place next to the overheat indicator light (Figure 1F). The
number 115 (for 110/120v) or 230 (for 220/240v) will be vis-
ible on the switch. The voltage should be veried and noted
by the installer and homeowner for possible troubleshooting
purposes in the future.
WARNING: Do not change the setting on the voltage
selector switch without verifying:
1. The incoming voltage from your power supply
2. The hardwire connections match your incoming
voltage according to the Dimplex BFSL33 Installa-
tion Instructions.
If they do not match it could lead to internal damage or non-
functioning components within the electric replace.
!
NOTE: If there is a need to change the voltage selector
switch position, ensure that the power to the unit
has been turned off and carefully insert a at head
screwdriver through the right side of the exhaust panel
into the notch on the switch. (Figure 1F) Then move
the switch either left or right to change it to the correct
position.
CAUTION: When changing the voltage selector switch,
ensure that the power supply is turned off.
Wall Mounted Controls
The replace can be installed with wall mounted controls.
These controls include wall switches, thermostats or wall
mounted remote controls. (See installation guide for de-
tailed installation instructions.)
1. Wall Mounted Switches
This model may be installed so that a wall mounted switch
energizes the rebox and dependent on the wiring can
control the operation/function of the ame and heat (On/
Off Switch must be in the ON position). For all wiring and
control options see the Installation Guide.
2. Wall Mounted Thermostat
This unit may be installed so that a wall mounted ther-
mostat can adjust the heat temperature to your individual
requirements. Please refer to thermostat manufacturers
operation Instructions.
3. Wall Mounted Remote Controls (WRCPF-KIT)
Dimplex manufactures a optional wall mounted remote
control which allows the user to fully control the replace
from a central location with the added functionality of a built
in thermostat.
MAINTENANCE
WARNING: Disconnect all power coming to replace
at main service panel before attempting maintenance
or cleaning to reduce risk of re, shock or damage to
persons.
Partially Reective Glass Cleaning
The partially reective glass is cleaned in the factory during
the assembly operation. During shipment, installation, han-
dling, etc., the partially reective glass surface may collect
dust particles. These can be removed by bufng lightly with
a clean dry cloth.
To remove ngerprints or other marks, the partially reec-
tive glass can be cleaned with a damp cloth using high
quality household glass cleaner. The partially reective
glass should be completely dried with a lint free cloth. To
prevent scratching, do not use abrasive cleaners or spray
liquids on any surface.