Installation Guide
15
G
L1 FROM UNIT
G FROM
POWER SUPPLY
G FROM UNIT
L1 FROM
POWER SUPPLY
NEUTRAL FROM
UNIT AND SUPPLY
UNIT
WIRE 1 FROM
G FROM UNIT
WIRE 2 FROM
G
2
1
2 CONDUCTOR WIRE
UNIT
FROM HEATER SWITCH
2
1
!
 NOTE: This only illustrates 
heater switch connection, 
see previous sections for 
main power connection 
instructions.
120V WALL MOUNTED THERMOSTAT
 CAUTION: The use of a wall mounted thermostat to control a 240V installa-
tion is not recommended. To control the unit with a thermostat the use of a 
Dimplex Wall Remote - WRCPF-KIT - is suggested (sold seperately).
!
 NOTE: Before installing the unit complete the following:
• Install main power connection with appropriate wiring - directly to the 
main power or through a wall switch.
• Install a 2 conductor wire with ground (3 wires total) from the thermostat 
wall box to the junction box on the unit.
!
 NOTE: Wiring of the thermostat must be completed prior to installing the 
FIREPLACE JUNCTION BOX 
WALL 
THERMOSTAT 
RED – 1 
GROUND - G 
RED – 2 