Installation guide
7
SECTION C: FACTORY SETTING WIRING
240 vo l T in s T a l l a T i o n
(Without Main Power Wall Switch)
!
IMPORTANT: The unit is factory congured for 208/240 volt operation
!
NOTE: Use 3 conductor wire with ground (4 wires total) from the power
supply (breaker panel) to the junction box on the unit.
!
NOTE: All wiring must be completed prior to installing the unit.
!
NOTE: Ensure that the voltage selector switch is in the proper position for
the required supply voltage prior to connecting the unit to the power sup-
ply.
Locate the voltage selector switch inside the exhaust panel on the top 1.
right hand corner of the unit.
Ensure that the switch is in the 240 volt position. (230 is printed on 2.
switch)
Loosen the screw securing the junction box cover and remove the cover.3.
Remove the knockouts (if necessary) or use the provided cable clamp.4.
Pull out the four wires marked L1, L2, N, and G.5.
Connect the black L1 wire from the unit to the black L1 from the power 6.
supply.
Connect the red L2 wire from the unit to the red L2 from the power supply.7.
Connect the white N wire from the unit to the to the white neutral from the 8.
power supply.
Connect the green ground wire from the unit to the ground from the power 9.
supply.
Ensure that all connections are tight.10.
Insert all the wiring back into the unit and secure with a cable clamp.11.
240 V
POWER
SUPPLY
(BREAKER
PANEL)
FIREPLACE JUNCTION BOX
WHITE WIRE - N
RED WIRE – L2
BLACK WIRE – L1
GREEN WIRE - G
WHITE WIRE - N
RED WIRE – L2
BLACK WIRE – L1
GROUND WIRE - G