Installation guide

5
SECTION A: FRAMING DIMENSIONS
Rough-In Framing Dimensions
Firebox Dimensions
Rough-In Corner Framing
This replace is a zero clearance design. No combustibles can be placed on
the top surface of the replace. Combustibles may be installed to the edge of
the unit. Four mounting anges on the sides of the unit are provided to facili-
tate installation. Insulation and vapor barrier should be placed a minimum of 2
inches from the unit.
SECTION B:
re C o M M e n d e d po W e r su p p l y Wi r e sp e C i f i C a T i o n s
For 120 volt installations use two conductor, non-metallic sheath cable with
ground wire (3 wires total) for the incoming power supply on replace inserts.
Use the appropriate wire to meet local and national electrical codes for rated
power consumption.
For 208 / 240 volt installations use three conductor, non-metallic sheath ca-
ble with ground wire (4 wires total) for the incoming power supply on replace
inserts. Use the appropriate wire to meet local and national electrical codes for
rated power consumption.
Two conductor, non-metallic sheath cable with ground wire (3 wires total) is
recommended for installation of a wall mounted thermostat and/or wall switch
for use on replace inserts. Use appropriate wire to meet local and national
electrical codes for rated power consumption. All wire gauges should match
the recommended wire sizes shown below.
re C o M M e n d e d Wi r e a n d fu s i n g re q u i r e M e n T s
Volts Wire Gauge Fuse Rating
120 Volts 12 Gauge 15 Amp
208 Volts 12 Gauge 15 Amp
240 Volts 12 Gauge 15 Amp