Product Info
OTDR
40
Figure 4.3-4-3
Reflectivity: the "reflectivity" box in the threshold parameter can change the
threshold of reflectivity. When "reflectivity" is checked, the test result will be
verified for reflectivity. When the reflectivity in the measurement result is greater
than the set value, the curve judgment will not pass, and the threshold range of
reflectivity is - 80 ~ 0dB.
For example, 1, 4 and 5 in figure (4.3-5) are reflection events (see Appendix A for
the meaning of event type icon), Then the values in the reflectivity column of 1, 4
and 5 will participate in the determination of reflectivity (the principle is consistent
with the determination of welding loss. When the welding loss is set to - 40, the
reflectivity values of event points 1 and 4 are less than - 40, so the reflectivity
column will not be marked in red, while the reflectivity column of event point 5 is
greater than - 40, the reflectivity value will be marked in red (Figure 4.3-5)).
Figure 4.3-5 Event point interface
Diameter distance loss: the "diameter distance loss" box in the threshold
parameter can change the threshold of diameter distance loss. When "diameter
distance loss" is checked, the test result will be verified for diameter distance loss.