Reference

Value (bit-packed number)
The current value of the parameter.
Error Codes
Get can return a number of errors:
0
No error occurred.
1
The channel is not started. Command Start on the channel.
2
The channel needs to be homed. Command Home on the channel.
3
A control error has occurred. Command Start on the channel to clear the control error.
4
The controller is in the wrong mode. For example, the DIP switches may be in mixed mode while the
tune was done in independent mode.
5
The parameter is unknown.
6
A serial timeout occurred, or the TX line was disconnected. Command Start on the channel to clear
the serial timeout.
System
See the particular system command's documentation.
Command Format
The command number for System is 37. Its data is:
Channel Name (1 byte)
Flags (1 byte)
0 for no options.
64 if a sequence code is used.
NOTE:
Tuning commands may have unusual effects on sequence code.
It is inadvisable to rely on sequence code consistency before and after a tuning command.
These effects are not necessarily limited to the channel being commanded.
12